MODELS B16-PF45 AND B20-PF65

SHORT FORM SPECIFICATIONS
The item shall be a sectional fryer with a stainless steel frypot and cabinet. The frypot shall have a large cold zone, and hanve widely spaced tubes to enable easy cleaning. The item
shall have a pilot ignition system and a 100% safety shutoff.

Printed in U.S.A.

NOTE: FOR COMMERCIAL USE ONLY

NOTE: The company reserves the right to make substitutions of components without prior notice

Dimensions are in inches and (millimeters)

SHIPPING CRATE DIMENSIONS & WEIGHT

(Door entry clearance when uncrated is

16.5” for model B16-PF45 and 20.5” for model B20-PF65)

Model

Width

Height Depth

Volume

Weight

B16-PF45

20.0

(508)

45.0

(1143)

42.5

(1080)

22.1 cu ft

(0.63 cu m)

210 lbs

(95 kg)

B20-PF65

23.0

(584)

41.0

(1041)

43.0

(1092)

23.5 cu ft

(0.66 cu m)

265 lbs

(120 kg)

31-3/4”

(808)

2” (51)

16” (406)

20” (508)

5-1/2”

(140)

7”

(178)

2-3/4” (70)

2-3/4” (70)

(Location of Optional Rear Gas Connection)

Model B16-PF45

Model B20-PF65

TOP VIEWS

Model B16-PF45

Model B20-PF65

FRONT VIEWS

36” Flue Riser

24” Flue Riser

36”

(914)

30”

(762)

6” (152)

60”

(1524)

72”

(1829)

SIDE VIEW

9” (178)

33-3/4”

(859)

4-1/2” (114)

Front Gas

Manifold

43-3/4” (1112)

40” (1017)

37-3/4” (960)

34” (864)

0(0)

Flue riser for “deep” depth-option extends rearward 6”

(frypot size is the same as for “standard” depth)

APPROVAL/STAMP

P/N BR00042 Rev A (2/08)

OTHER TECHNICAL INFORMATION

If casters are used with flex hose, a restraining device should be used to eliminate undue strain on the flex hose.

Minimum clearance from non-combustible construction is zero. Minimum clearance from combustible construction is 10” on sides and 6” on rear.

Check local codes for fire and sanitary regulations.

UTILITY INFORMATION

GAS: Each unit has a 1-1/4" front gas manifold that couples to the adjacent sectional unit(s), and can be ordered with a 1" rear
gas connection with a male NPT connector. Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. All sec-
tional units require a regulated gas supply; pressure regulator to be ordered separately. If using a flexible-hose gas connection, the
I.D. of the hose must not be smaller than the connector on the unit and must comply with ANSI Z21.69. Provide an adequate
means of restraint to prevent undue strain on the gas connection.

FLUE EXHAUST: Installation under a vented hood is recommended.

MODEL

GAS (BTU/hr)

Natural Gas

Propane

B16-PF45

110,000

110,000

B16-PF65