Baldor MN781-SUP User Manual

Baldor Microwaves

Advertising
background image

Baldor Electric Company, P. O. Box 2400, Ft. Smith, AR 72902-2400, (479) 646-4711, Fax (479) 648-5792

6HULHV  0LFUR ,QYHUWHU 6XSSOHPHQWDO ,QIRUPDWLRQ

Part No. MN781-SUP

(A42126) - Rev. D2 - 1/29/2004 - Z2746D02

Page 1 of 2

IMPORTANT: The following information and instructions are to be used as a supplement to the Installation and Operation
Manual (Part No. MN781) until the new manual is available with the addition of Model ID5602-CO. The manual must be read
and understood before attempting to operate this control.

Table 1 - Electrical Ratings

Catalog No.

Input Voltage

(Volts AC - 50/60 Hz)

Nominal

Output Voltage

(Volts AC)

Maximum

Horsepower Rating

(HP (kW))

Maximum

Continuous Output

Load Current

(RMS Amps/Phase)

Maximum

AC Line Input Current

(Amps AC)

ID5602-CO

115/230

0 - 230

1½* (1.13)

5.5**

22.0/14.0

Notes: * The control can operate most premium efficiency motors rated 2 HP.

** CL Trimpot Range (Amps AC): 3.5 - 10.5 (Factory Setting: 8.8).

Figure 1 - Mechanical Specification and Control Layout (Inches/mm)

The control is shown set for 115 Volts AC line input (Jumper J1 in the "115V" position).

For 230 Volts AC line input, set Jumper J1 to the "230V" position (factory setting).

 6HWWLQJ 6HOHFWDEOH -XPSHUV

This control has customer selectable jumpers which may have to be set before the control can be used. See Mechanical
Specifications and Control Layout, above, for the location of jumpers.
WARNING! Disconnect the AC line before changing position of jumpers.

1-1. AC Line Input Voltage Selection (Jumper J1 on Upper PC Board): The ID5602-CO can operate standard 208 -

 9ROW $&   +]  

LQGXFWLRQ PRWRUV IURP HLWKHU  RU  9ROW   +]  

$& OLQH LQSXW

7KH

control is factory set to operate from a 208/230 Volt AC line input (Jumper J1 in the "230V" position). To operate the
control from a 115 Volt AC line input, set Jumper J1 to the "115V" position. See Figures 2A and 2B, on next page.

WARNING! Do not change jumper position with the AC line connected.

WARNING! Be sure proper input voltage is applied to the control corresponding to jumper setting.
Connecting a 230 Volt AC line with Jumper J1 set to the "115V" position will permanently damage the
control. "115VAC" and "230VAC" labels are provided. Use the appropriate label to identify the correct input
voltage after setting Jumper J1. See Figures 2A and 2B on page 2 of this supplement.