Bunn -O-Matic Brewer Axiom User Manual

Page 14

Advertising
background image

Page 14

PROBABLE CAUSE

REMEDY

PROBLEM

TROUBLESHOOTING

Temperature Too Low

Heating Time Too Long

Fill Time Too Long

Temp Sensor Out Of Range,
Check For Bad Connections

Temp Sensor Out Of Range,
Check Wire For Shorts

Equipment will not operate

Water fl ows into tank continu-
ously with power removed from
brewer.

1. Water temperature in the
tank does not meet the ready
temperature.

1. Tank Heater failure.

2. Control Board/Thermistor
failure

1. Water shut off to brewer

2. Supply line too small or ob-
structed

3. Inlet Solenoid failure

4. Control Board Failure

5. ON/OFF switch is OFF

1. Temperature Sensor Probe
wire(s) broken or not making
connection

1. Temperature Sensor Probe
wire(s) shorted to housing or
to each other.

1. No power

2. Incorrect voltage

1. Refi ll valve

A) Wait for the brewer to heat
to the proper temperature.

B) Disable the BREW LOCK-
OUT function. Refer to program-
ming section for procedure.

Service required

Service required

Check water supply shut-off

Replace or repair as needed

Service Required

Service Required

Turn switch ON

Service required

Service required

Verify power cord is plugged
into outlet.

Service required

Service required

41154 041708