Modulated remote sensors require specially

designed cable for efficient sensor performance.

Extension cable is available in 100 foot (30m)

lengths.

Extension Cable

used with the compression fittings, at

right, to achieve maximum protection

to sensor cables.

I.D. = 5/16"; O.D. = 7/16".

Accessories for High Performance Modulated Remote Sensors

PVC-6 6 feet (1,8m)

PVC-30 30 feet (9m)

Hookup of LR300 and PT300

Hookup of SP300D, SP300L, LP400WB, SP1000V

Hookup of SP320D

Sensor Hookup Diagrams for MA3-4 MICRO-AMP Modules

(continued)

Remote sensor cables may be run up to 30 feet (9m) away from the MA3-4

amplifier. All sensor models are available from the factory with 30 feet of

cable, installed as an option.
When splicing additional cable to the standard 6-1/2 foot length, it is

important to use a separate shielded cable for emitter and receiver wires.

Combining emitter and receiver wires together in the same cable (even if

the cable is shielded) will result in direct coupling of the emitter signal to

the receiver leads.
This is called "cable crosstalk" and will not allow full amplifier sensitivity

setting without an amplifier "lock on" situation, which appears as a con-

tinuous LIGHT condition. Banner offers 100 foot (30m) lengths of sensor

extension cable (see below) which, if used for cable splicing, will minimize

the chances for cable crosstalk.

IMPORTANT : Cable Splicing Information

WARNING

MICRO-AMP

®

Systems do NOT

include the self-checking redundant circuitry neces-

sary to allow their use in personnel safety applica-

tions. A sensor or amplifier failure or malfunction

can result in either an energized or a de-energized

output condition.

Never use this product as a sensing device for personnel protection. Its

use as a safety device may create an unsafe condition which could lead

to serious injury or death.

Only MACHINE-GUARD and PERIMETER-GUARD Systems, and

other systems so designated, are designed to meet OSHA and ANSI

machine safety standards for point-of-operation guarding devices. No

other Banner sensors or controls are designed to meet these standards, and

they must NOT be used as sensing devices for personnel protection.

Heavy duty PVC tubing used to

protect sensor cable in applications

involving moisture and/or corrosive

materials. I.D. = 1/4"; O.D. = 3/8".

Extension Cable
Model

ESC-100

RSC-100

SSC-100

EC300E-100

EC300R-100

EC320-100

Used on Sensor Models

# of
Wires

Wire Colors

White, Green, Shield

Red, Black, Shield

White, Green, Red, Black,

Shield

White, Shield

Red, Shield

White, Shield, Red, Shield

PT200, PT250, PT400,

SP300RL

LR200, LR250, LR400,
SP300EL

SP300D, SP300L, LP400WB,

SP1000V

LR300

PT300

SP320D

3

3

5

2

2

4

Banner Engineering Corp. 9714 10th Avenue No., Minneapolis, MN 55441 Telephone: (763) 544-3164 FAX (applications): (763) 544-3573

Cable Protection

AC-6 6 feet (1,8m)

AC-30 30 feet (9m)

This is mild-steel flexible tubing