Panel descriptions, Vmix rear panel – Bogen VMIX User Manual

Page 5

Advertising
background image

Panel Descriptions

VMIX Rear Panel

1. AC Receptacle

A grounded, unswitched AC convenience receptacle with a 500W maximum capacity is provided for external
equipment.

2. Unbalanced Output Jack

Provides an unbalanced output for connection to an auxiliary or high-impedance input.

3. Bridging Jack

An RCA connector that allows the bridging of Power Vector products together for system expansion.

4. Remote Volume Control Terminals

Three terminals are provided for connection to a Bogen Model RVCP, Remote Volume Control Panel, to
control the mixer’s motorized Master Volume Control.

5. Low-Cut Switch

A slide switch (located in module bay 6) that allows roll off of frequencies below 125 Hz.

6. Tone Control Bypass Switch

A slide switch (located in module bay 6) that allows the effects of the bass and treble controls to be bypassed.

7. AC Line Cord and Circuit Breaker

A grounded, 3-wire AC line cord provides power to the mixer and is protected by a resettable circuit breaker.

8. Balanced Out Level Switch

Three-position slide switch that selects the signal level of the balanced output.

9. Balanced Out Terminals

Provides a balanced transformer-isolated output with selectable output levels.

10. Mute Control Terminals

Provides access to mute buses for external control and system expansion.

11. Module Bays

The mixer has eight module bays, all of which can accommodate input modules, with two bays (bays 7
and 8) that can accommodate either input or output modules.

3