FIG 18 JDF-4S

FUNCTION LIST (Continued)

3

1
2

4

5

P3845

Circuit Board LED Indicators - JDF-4S and Late Model JDF-2S

LED #

LED Color

Illuminates:

1 Bath

Red

When bath temperature is above 34 degrees F.

Flashes slowly when compressor is in a 6 minute delay period.

Open bath thermistor circuit will flash #1 and #2 LED’s 1 time every 3
seconds. The compressor will not run under this condition.

Shorted bath thermistor circuit will flash #1 and #2 LED’s 2 times every 3
seconds. The compressor will not run under this condition.


2 Bath

Green

When bath temperature is below 34 degrees F.


3

Green

When the compressor should be ON.


4 Cabinet

Red

When the cabinet temperature is above 50 degrees F.


Flashes slowly when cabinet temperature exceeds 50 degrees F for 4
hours. Dispense functions are locked out under this condition. Power
down the dispenser to reset.

Flashes rapidly if dispense is attempted in lockout condition.

Open cabinet thermistor circuit will flash #4 and #5 LED’s 1 time every 3
seconds.

Shorted cabinet thermistor will turn #4 and #5 LED’s on steady.


5 Cabinet

Green

When cabinet temperature is below 50 degrees F.