GB-18

Drain out water within the unit in the following cases.

• When the unit stops operating and the orange TIMER lamp, the green AIR CON lamp

and the red MAXIMUM lamp are blinking, the water tank is full and need to be drained.

• When the unit is not used for a long time.

1

Unplug the power plug and carefully move

the unit to a drain or outside to avoid wa-

ter spilling out into the room.

2

Remove the stopcock from the drainpipe,

and drain water within the unit.

3

Attach the stopcock securely to the drain-

pipe.

MAIN UNIT OPERATION

1

1

Press the POWER button to start opera-

tion.

• The mode will change as you press the button

within 5 seconds.

• In cool mode, the unit will operate at its last

cooling settings. If the unit has been unplugged

since it was last operated, it will resume opera-

tion in the cooling mode, set at 20˚C. The fan

speed set to AUTO.

TO TURN OFF

Press the POWER button during opera-

tion.

Stopcock

Drainpipe

DRAINAGE

Use this operation when the remote control is not available.

COOL

(The green AIR CON lamp will light)

ION GENERTOR

(The blue ION GENERATOR lamp will light)

OFF

01_CV-P10PR_OM_EN.indd 18