Bosch BOSCH WALL OVENS User Manual

Page 6

Advertising
background image

4 • English

Safety Instructions

Preparation

Installation

Final Steps

Step 4: Connect Electric

4. Connect Electric

Verify that electric to the junction box has been turned

off before beginning this step.
General Instructions:

Use copper wire ONLY. Wire size and connections

must be suitable for the rating of the appliance per

the National Electrical Code requirements or the

Canadian Electric Code requirements.

The flexible conduit extending from the oven

should be connected directly to the junction box.

• Do not shorten flexible conduit.

The junction box should be located to allow as

much slack as possible between the junction box

and the oven.

A UL listed conduit connector must be provided at

each end of the power supply cable.

The four wire branch circuit connection is

preferred, but where local codes permit, a three

wire branch circuit connection is also acceptable.

Four Wire Connection (Preferred Method):
1. Connect green ground wire from oven to green (or

bare) ground wire in junction box.

2. Connect red wire from oven to red wire in junction

box.

3. Connect black wire from oven to black wire in

junction box.

4. Connect white wire from oven to white (or gray)

neutral wire in junction box.

Three Wire Connection :
Note:
The four wire connection is preferred, but

where local codes permit, the three wire connection is

also acceptable.
1. Connect red wire from oven to red wire in junction

box.

2. Connect black wire from oven to black wire in

junction box.

3. Connect both green ground wire and white wire

from oven to white (or gray) neutral wire in

junction box.

Connecting to a 208 V circuit (700 Series):
The oven is pre-wired for connection to 240 V, 60 Hz supply,

but can be converted for use with 208 V, 60 Hz supply.
1. Turn power on a breaker.
2. Open oven door (upper oven in double ovens)
3. Press CANCEL.
4. Turn knob clockwise until 6 double beeps sound.
4. Turn knob couonterclockwise until 9 double beeps

sound.

5. Press START.
6. Press COOKING MODE.
7. Press START.

Time of day clock appears in display.

Figure 4: Four Wire Connection

Figure 5: Three Wire Connection

Connecting to a 208 V circuit (5000 Series):
The oven is pre-wired for connection to 240 V, 60 Hz

supply, but can be converted for use with 208 V, 60 Hz

supply.
1. Turn power on a breaker.
2. Press and hold SET CLOCK and TIMER for at

least three seconds.

Sele dEG appears in display.

3. Press and hold STOP TIME and TIMER for at

least three seconds.

Display is blank.

4.

Press and hold COOK TIME and STOP TIME

for at least three seconds.

VOLT 240 is displayed.

5. Press SET CLOCK.
6. Press + or - to select appropriate voltage (choose

208 for 208 V connection; choose 240 to 240 V

connection).

7.

Press SET CLOCK.

8. Press and hold STOP TIME and TIMER for at

least three seconds.

Sele dEG appears in display

8. Press and hold SET CLOCK for at least three

seconds.

Time of day clock appears in display.

Advertising