SERVICE (cont.)

TANK HEATER SWITCH (cont.)

15. Set tank assembly inside the hood on mounting

brackets and secure with two #8-32 screws.

16. Reconnect the wires to the limit thermostat, tank

heater and the control thermostat. Refer to limit
thermostat, tank heater and control thermostat
sections in this manual when reconnecting wires.

17. Brewers with faucet reinstall the faucet tube and

reconnect the water supply tube to the coil as-
sembly.

18. Secure the sprayhead tube to the hood using hex

nut.

19. Install sprayhead.
20. Install fill basin, inlet gasket and secure to tank lid

with tank inlet fitting.

21. Carefully install water fill tube into the back of the

fill basin.

22. Reconnect and turn on the incoming water sup-

ply.

23. Refer to the illustration below when reconnecting

the wires.

BLK to Terminal Block
(Black Insert)

BLK to Limit Thermostat

P1135