A. PILOT BURNER LIGHTING PROCEDURE:

(a) Partially depress and turn the gas cock dial to ‘OFF’(•) position.
(b) Wait for five minutes to allow gas, which may have accumulated in the burner compartment, to
escape.
(c)Turn gas cock dial to ‘PILOT’(

*) position.

(d) Depress gas cock dial and light Pilot Burner. Hold in pressed position for about ½ minute (30
Seconds), and release the gas cock dial. The Pilot Burner should now remain lit.
If Pilot Burner fails to ignite or does not remain lit, repeat the steps (a) through (d).

B. PILOT BURNER FLAME ADJUSTMENT:
It

is

important

to

have

the

correct

Pilot

Burner

Flame

size

as

shown

in

Fig.10.

If

necessary,

adjust

the

Pilot

Burner

Flame

by

turning

Pilot

Adjust

Screw

(See

fig.

11)

clockwise

to

reduce

or

counter-

clockwise to

increase.

3/8”-1/2”

Correct Flame

Figure #10

Figure #11

Thermostat

Pilot

Feed

Gas

Cock

Dial

Pressure

Regulator

Pilot

Adjust
Screw


8. BURNER OPERATION:
(a) MAIN BURNER:
After the pilot burner is ignited, when heat is desired, turn gas cock dial to ‘ON’ (

Ù) position and set the

thermostat dial to the desired temperature. The oven burner flame should always have a blue
appearance. That indicates a good mixture of gas and air. When using LP gas, the flame will have a
blue-yellow appearance.
Should the Burner fail to light, check to see if there is a problem with the gas supply. If there are other
appliances on the same line, shut them off temporarily and see if the burner comes back on, or it
fluctuates as other gas appliances are turned on and off. That would indicate overloading of the gas
supply lines or a faulty gas pressure regulator. Contact an authorized Service Agency or your local Gas
Supply Company.

(b) AERATION AND BY-PASS FLAME ADJUSTMENT
:
Flame and air mixer adjustments and the By-Pass Flame adjustment for the Main Burner are done at
the factory. These adjustments are sealed before the oven leaves the factory. Contact an authorized
Service Agency if you need help.

9. THERMOSTAT CALIBRATION:
No attempt should be made to calibrate the thermostat because it is accurately calibrated and sealed by
the manufacturer. Contact an authorized Service Agency if you need help.


8