Maintenance

60

11.

Restart the projector.

Do not turn the power on with the lamp cover removed.

Resetting the lamp timer
12.

After the startup logo, open the On-Screen
Display (OSD) menu. Go to the SYSTEM
SETUP: Advanced > Lamp Settings menu.
Press Mode/enter on the projector or ENTER
on the remote control. The Lamp Settings
page displays. Highlight Reset Lamp Timer. A
warning message displays asking if you want
to reset the lamp timer. Highlight Reset and
press Mode/enter on the projector or ENTER
on the remote control. The lamp time will be
reset to '0'.

Do not reset if the lamp is not new or replaced as
this could cause damage.

10.

Use a coin to turn the screw clockwise until the
lamp cover is secured.

Loose screw may cause a bad connection, which
could result in malfunction.

Do not over tighten the screw.