fittings must be used and all connections tested for gas
leaks.
The supply connection point shall be accessible with the
appliance installed.
WARNING: Ensure that the hose assembly is restrained
from accidental contact with the flue outlet of an
underbench oven.
Before Leaving- Check all connections for gas leaks with
soap and water. DO NOT use a naked flame for detecting
leaks. Ignite all burners both individually and concurrently
to ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and observe
stability of the flame for each burner individually and all
together. Adhere the duplicate data plate to an
accessible location near the hotplate. When satisfied with
the hotplate, please instruct the user on the correct
method of operation. In case the appliance fails to
operate correctly after all checks have been carried out,
refer to the authorised service provider in your area.
It should be expressly noted that we cannot accept any
liability for direct or indirect damage caused by wrong
connection, leakage or improper installation. When being
repaired, the appliance must always be disconnected
from the mains supply; if required, notify our customer
service.

Converting the
cooktop from Nat.
Gas to Propane Gas

To change injectors

All work involved in installation, setting and adaptation to
a different gas type must be carried out by authorised
personnel from our Service Centre and must comply with
current regulations and the conditions laid down by the
local gas company.
Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).

Natural Gas

Propane Gas

Burner

Hourly Gas

Consumption

(MJ)

Injector

mark

(mm)

Hourly Gas

Consumption

(MJ)

Injector

mark

(mm)

Small

4,80

97

3,50

53

Medium

8,10 130

6,00

70

Large

11,60

157

8,50

83

wok (inner)

22,00

65

20

47

wok (outer)

215

115

distanze
“Z’’

11

12

Advertising