17

+

A

C

A

C

SERVICE (cont.)

Removal and Replacement:
1.

Disconnect the wires from the rectifier.

2.

Remove the #10-32 screw securing the rectifier
to the motor mounting bracket.

3.

Remove the rectifier and discard.

4.

Install new rectifier on the rear of the motor
mounting bracket and secure with a #10-32
screw.

5.

Refer to Fig. 13 and reconnect the wires.

BLK from Motor (+)

BLU to BLU from Motor (AC)

WHI from Main Harness (AC)

RED from Motor (-)

FIG. 13 RECTIFIER TERMINALS

P1381

RECTIFIER - G1MD ONLY

CLE

ANIN

G LEVER

CLEANING LEVER

GR

OUND