240-Volt Electric Compact Dryer

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

LER3622P

Electrical:

A four-wire or three-wire, single

phase, 120/240-volt, 60-Hz, AC-only, electrical
supply (or 120/208-volt electrical supply, if
specified on the serial/rating plate) is required on a
separate 30-ampere circuit, fused on both sides of
the line. Use 10 gauge solid copper wire. A time-
delay fuse or circuit breaker is recommended.

Exhaust venting:

Exhaust your dryer to the

outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
Not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. 8562114

09-08-04

23

7

8

(60.6 cm)

"

20

3

4

(52.7 cm)

"

31"

(78.7 cm)

*

Number of

90

° turns

or elbows

Type of

vent

Box or

louvered

hoods

Angled

hoods

0

Rigid metal
Flexible metal

36 ft (11 m)
28 ft (8.5 m)

26 ft (7.9 m)
22 ft (6.7 m)

1

Rigid metal
Flexible metal

26 ft (7.9 m)
18 ft (5.5 m)

16 ft (4.9 m)
12 ft (3.7 m)

2

Rigid metal
Flexible metal

16 ft (4.9 m)
8 ft (2.8 m)

6 ft (1.8 m)
2 ft (0.6 m)

4"

(10.2 cm)

2.5"

(6.4 cm)

Louvered style

Angled style

4"
(10.2 cm)

4"
(10.2 cm)

Box hood style

A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents

A B C

in.

in.

A. Side view - closet or confined area
B. Recessed area

B

A

Recessed or closet installation - Dryer only

Recessed or closet installation - Stacked

Closet confined area

For closet installation with a
door, minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
air openings are acceptable.

*Most installations require a

minimum 5-1/2 in. (14.0 cm)
clearancebehind the dryer for the
exhaust vent with elbows.

1. Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns. When using
elbows or making turns, allow as much room as possible. Bend vent gradually to
avoid kinking. Avoid 90° turns when possible.

2. Determine vent length.

The maximum length of the exhaust system depends upon:

• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.

See the exhaust vent length chart that matches your hood type for the maximum
vent lengths you can use.

3. Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.

In the column listing the type of metal vent you are using (rigid metal or flexible
metal), find the maximum length of metal vent on the same line as the number of
elbows.

Advertising