Whirlpool LTG5243DQ User Manual

Gas thin twin washer/dryer

Advertising
background image

Minimum

installation

spacing

Closet

confined

area

Recessed

area

Minimum

installation

spacing

®

Gas Thin Twin Washer/Dryer

PRODUCT MODEL NUMBER

OVERALL DIMENSIONS

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

LG5243DQ

Gas supply:

Dryer is equipped for use with

NATURAL gas. Dryer can be converted to L.P. gas.
When rigid pipe is used it should be 1/2 inch IPS.
When acceptable to the gas supplier and local
codes, 3/8-inch approved tubing may be used for
lengths under 20 feet. For lengths over 20 feet,
larger tubing should be used. Pipe-joint
compounds resistant to the action of L.P. gas must
be used. This washer/dryer is equipped with its
own permanent, flexible gaas connector, design-
certified by CSA International, for connecting the
appliance to the gas supply line. An individual
manual shutoff valve must be installed within 6
feet of the dryer in accordance with the National
Fuel Gas Code ANSI Z223.1.

Electrical:

A 120-volt, 60-Hz, AC-only, electrical

supply is required on a seperate 15- or 20-ampere
circuit, fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended.

Exhaust venting:

Exhaust your dryer to the

outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
Not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. 3405971

06-01-02

4-3/8"

recess

depth

1-1/2"

14-1/4"
recess width

rear view

cold

water inlet

28-5/8"

24"

drain
outlet
27-1/2"

exhaust

outlet

38"

19"

12"

12"

71-3/4"

27-1/4"

side view

38"

5-1/4"

21-5/16"

15-3/8"

32-1/8"

57"

47"

51-1/2"

27-5/8"

0"

side view

12"

0"

dryer

washer

front view

0"

48 sq. in.*

24 sq. in.*

24 sq. in.*

3"

3"

front view

side view

48 sq. in.*

0"

Unobstructed air openings are minimum for closet door.
Louvered door with equivalent air openings is acceptable.

1"

closet
door

closet
door

The maximum length using a 2" x 6" rectangular vent
with 2 elbows and a 2-1/2" exhaust hood is 8 ft.

43 ft
33 ft
23 ft
18 ft

0
1
2
3

41 ft
31 ft
21 ft
18 ft

29 ft

23 ft
15 ft

9 ft

24 ft
18 ft
10 ft

Not

recommended

36 ft
26 ft
16 ft

Not

recommended

0
1
2
3

flexible
metal
vent.

rigid
metal
vent.

Maximum
length of
4" dia.
vent.

4"

4"

2-1/2"

NUMBER
OF 90°
TURNS

30 ft
24 ft
16 ft
10 ft

Plan installation to use the fewest number of
elbows and turns.
Maximum length
of the exhaust system depends
upon the type of vent used, number of elbows and
the type of exhaust hood. The maximum length for
both rigid and flexible vent is shown in the chart.

Additional clearance for wall, door and floor molding may be
required. Additional space may be needed for exhaust elbow.