Danger, Warning – Blue Rhino SV3100 User Manual

Page 2

Advertising
background image

Outdoor LP Gas Mosquito Exterminator Model No. SV3100

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

DANGER

If you smell gas -

1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance immediately and call

your gas supplier or your fire department.

WARNING

FOR YOUR SAFETY

1. Do not store or use gasoline or other flammable liquids or vapors in the

vicinity of this or any other appliance.

2. An LP cylinder not connected for use shall not be stored in the vicinity

of this or any other appliance.

This SkeeterVac

®

is for outdoor use only, and shall not be used in a

building, garage, or any other enclosed area.

Do NOT operate, light or use this appliance within 8 feet of walls,

structures, buildings or combustible materials.

It is a violation of Federal law to use this product in a manner

inconsistent with its labeling.

This SkeeterVac

®

is NOT for commercial use.

This SkeeterVac

®

is for use with liquid propane (LP) gas only.

The conversion to or attempted use of natural gas in this LP gas

SkeeterVac

®

is dangerous and will void your warranty.

LP gas Characteristics:

a. LP gas is flammable and hazardous if handled improperly. Become

aware of the characteristics before using any LP gas product.

b. LP gas is explosive under pressure, heavier than air, and settles and

pools in low areas.

c. LP gas in its natural state has no odor. For your safety, an odorant is

added that smells like rotten cabbage.

d. Contact with LP gas can cause freeze burns to skin.

LP gas tank needed to operate. Only tanks marked “propane” may be

used.

a. The LP gas supply tank must be constructed and marked in

accordance with the Specifications for LP gas Cylinders of the

U.S. Department of Transportation (DOT) or the National Standard

of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for the

Transportation of Dangerous Goods; and Commission.

b. LP gas tank must be arranged for vapor withdrawal.
c. The LP gas tank must have a listed overfilling prevention device

(OPD).

d. Only use 20-pound cylinders equipped with a cylinder connection

device compatible with the connection for outdoor cooking

appliances.

e. The LP gas tank must have a tank collar to protect the tank valve.
f. Never use an LP gas tank with a damaged body, valve, collar, or

footing.

g. Dented or rusted LP gas tanks may be hazardous and should be

checked by your LP gas supplier prior to use.

h. The LP gas tank should not be dropped or handled roughly.
i. Tanks must be stored outdoors out of the reach of children and must

not be stored in a building, garage, or any other enclosed area. Your

tank must never be stored where temperatures can reach over 125°F.

j. Never keep a filled LP gas tank in a hot car or car trunk. Heat will

cause the gas pressure to increase, which may open the relief valve

and allow gas to escape.

k. Place dust cap on cylinder valve outlet whenever the cylinder is not in

use. Only install the type of dust cap on the cylinder valve outlet that

is provided with the cylinder valve. Other types of caps or plugs may

result in leakage of propane.

l. Do not store a spare LP gas tank under or near this appliance.
m. Never fill the tank beyond 80 percent full.
n. A fire causing, serious injury or damage to property may occur if the

above is not followed exactly.

o. Always transport your tank in a secure, well-ventilated location in

your vehicle. LP gas tank should be upright with valve turned off. LP

gas tank should be taken directly to and from place of use.

Never attempt to attach this SkeeterVac

®

to the self-contained LP gas

system of a camper trailer, motor home, or house.

The use of alcohol, or prescription or non-prescription drugs may

impair the consumer’s ability to properly assemble or safely operate the

appliance.

Your SkeeterVac

®

has been checked at all factory connections for

leaks. Recheck all connections, as movement in shipping can loosen

connections.

Check for leaks even if your unit was assembled for you by someone

else.

Do not operate if gas leak is present. Gas leaks may cause a fire or

explosion.

You must follow all leak-checking procedures before operating. To

prevent fire or explosion hazard when testing for a leak:

a. Always perform leak test before lighting the SkeeterVac

®

and each

time the tank is connected for use.

b. No smoking. Do not use or permit sources of ignition in the area

while conducting a leak test.

c. Conduct the leak test outdoors in a well-ventilated area.
d. Do not use matches, lighters, or a flame to check for leaks.
e. Do not use SkeeterVac

®

until any and all leaks are corrected.

If you are unable to stop a leak, disconnect the LP gas supply. Call a

gas appliance serviceman or your local LP gas supplier.

Do not store or use gasoline or other flammable liquids or vapors within

25 feet (7.62 m) of this appliance.

Do not use in an explosive atmosphere. Keep SkeeterVac

®

area clear

and free from combustible materials, gasoline and other flammable

vapors and liquids.

Minimum clearance from sides and back of unit to combustible

construction, 21 inches from side and 21 inches from back. Do not use

this appliance under overhead combustible surfaces.

It is essential to keep the SkeeterVac®’s valve compartment, burners,

and circulating air passages clean. Inspect SkeeterVac® before each

use.

Do not alter SkeeterVac

®

in any manner.

Do not use the SkeeterVac

®

unless it is COMPLETELY assembled and all

parts are securely fastened and tightened.

This SkeeterVac

®

should be thoroughly cleaned and inspected on

a regular basis. Clean and inspect the hose before each use of the

appliance. If there is evidence of abrasion, wear, cuts, or leaks, the

hose must be replaced prior to the appliance being put into operation.

Use only the regulator and hose assembly provided. The replacement

regulator and hose assembly shall be that specified by the

manufacturer.

Use only Blue Rhino Global Sourcing, Inc. factory authorized parts. The

use of any part that is not factory authorized can be dangerous. This

will also void your warranty.

Do not use this appliance without reading “Operating Instructions” in

this manual.

Do not install or use in or on boats or recreational vehicles.
Product performance can vary due to weather, wind and other

environmental conditions.

Never lean over the SkeeterVac

®

when lighting.

Do not attempt to move SkeeterVac

®

when in use. Allow the

SkeeterVac

®

to cool before moving or storing.

Storage of SkeeterVac

®

indoors is permissible only if the tank is

disconnected, removed from the SkeeterVac® and properly stored

outdoors.

Do not attempt to disconnect the gas regulator from the tank or any gas

fitting while the SkeeterVac

®

is in use.

Do not use SkeeterVac

®

for indoor cooking or heating. TOXIC fumes can

accumulate and cause asphyxiation.

After a period of storage and/or nonuse, check for leaks, burner

obstructions and inspect for any abrasion, wear, cuts to the hose.

If SkeeterVac

®

is not in use, the gas must be turned off at the supply

tank.

Keep air intake areas clear of dust, dirt and debris
Do not allow children to operate or play near a SkeeterVac

®

device

when it is in use.

Inspect for damage and wear during each maintenance cycle.
It is recommended to use only FineTune

®

mosquito attractant in your

SkeeterVac

®

. The use of other attractants has not been tested with your

product, and void your warranty.

Maximum inlet gas supply pressure is 11 inch water column
Deaths, serious injury or damage to property may occur if the above is

not followed exactly.

DANGER: Failure to follow the dangers, warning and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion

causing damage to property.

WARNING:

Advertising