Page

11 of 12

WARNING

A minimum of one (1) inch clearance must be maintained between the supply air duct and combustible materials. This is
required for the first three (3) feet of ducting.

It is important to insure that the one (1) inch minimum spacing is maintained at all points.

Failure to do this could result in overheating the combustible material and may result in a fire causing damage, injury or death.

F

G

N

P

D

DD

FF

GG

HH

A

M

I

C

K

J

L

H

R

S

S

S

S

S

T

V

Y

AA

X

U

Z

CC

BB

B

EE

O

E

B

II

Q

W

1

1

PANEL (LOCKABLE)

PANEL

CONDENSER

AIR OUTLET

BACK

RETURN OPENING

SUPPLY OPENING

GAS
ENTRANCES

AIR EXHAUST

COMBUSTION

CONDENSER
AIR INLETS

4 DEG. PITCH IN TOP

VESTIBULE
DOOR

COMBUSTION
AIR INTAKE

VENT OPTION

PANEL DOOR

CIRCUIT BREAKER/

CONTROL

FRONT

DISCONNECT ACCESS

RIGHT SIDE

ENTRANCES

LOW VOLTAGE

HIGH VOLTAGE
ENTRANCES

FRONT DOOR

MIS-3240 B

FILTER
SERVICE
DOOR

UNIT

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

WG3S2

31.63

87.5

33.38

28.75

WG4S2/WG5S2

41.63

97.5

43.38

38.75

UNIT

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

EE

FF

GG

HH

II

WG3S2

3.75

24.9

WG4S2/WG5S2

13.75

34.9

3.75

16

9.88

29.88

15.88

27.25

1.25

7.25

1.13

4.5

12.19

10

40.25

43.81

0.44

15.31

2.25

3.88

42

17.34

8.44

3.25

2.75

2.5

14.88

30

14.12

15.44

42.88

s

e

c

n

a

r

a

e

l

C

m

u

m

i

n

i

M

)

s

l

a

i

r

e

t

a

m

e

l

b

i

t

s

u

b

m

o

c

m

o

r

f

(

t

c

u

D

t

e

l

t

u

O

'

3

t

s

r

i

f

"

1

)

s

l

a

i

r

e

t

a

m

e

l

b

i

t

s

u

b

m

o

c

m

o

r

f

(

l

a

n

i

m

r

e

T

t

n

e

V

"

7

1

t

e

l

t

u

O

r

e

s

n

e

d

n

o

C

"

0

2

p

o

T

1

e

r

u

g

i

F

e

e

S

e

c

i

v

r

e

S

r

e

n

r

u

B

"

0

2

C

r

o

B

,

A

s

s

a

l

C

r

o

d

o

o

W

(

e

s

a

B

e

l

b

it

s

u

b

m

o

C

)

l

a

i

r

e

t

a

m

g

n

i

r

e

v

o

c

f

o

o

r

"

0

FIGURE 1

COMBUSTIBLE CLEARANCE

DIMENSIONS OF BASIC UNIT

1 Optional top outlet in place of standard front supply opening, see

Nomenclature outlet options (next page). Standard unit can also be
field converted to this configuration using approved top supply outlet
conversion kit shown on next page.

Advertising
This manual is related to the following products: