Eng lish – Bosch ATM/POS Bridge User Manual

Page 12

Advertising
background image

Bosch Security Systems

ATM/POS bridge | Installation Manual

EN |

6

Eng

lish

4. Connect your terminal to COM port 1, 2, 3 or 4 of the bridge using the supplied

cable. Choose the COM 4 port on the bridge if your connection protocol is RS485.

Normally, you would use the supplied splitter cable to make this connection. For
example, you remove the existing cable that connects your terminal to the
printer. Use the supplied splitter cable to connect the terminal to the printer.
The third connector of the splitter cable then connects to the supplied
connection cable which connects to the bridge.

To select the communication parameters for the ports and the network parameters, use a
PC to start a configuration session as described below. The activity LED lights when the
bridge is active.

Note

To download firmware to the bridge you must use the supplied RS232 cable connected
to the COM3 (console) port. In this situation the cable must be connected to the bridge
before it is powered.

POS terminal

Printer

Digital
Video
Recorder

Ethernet
cross-over
cable

ATM/POS
bridge

Supplied splitter
cable

Supplied
connection cable

Advertising