BEA Stanley Dip Switch I User Manual

Page 15

Advertising
background image

SIZE:

DRAWN BY:

B

100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com

REV BY:

KJG

TUC

SCALE:

DATE:

NONE

02 DEC 2005

PART NO:

SHEET
1 OF 1

NOTES: 1 ) MAGIC FORCE AUX. SWITCH #4 SHOULD OPEN AT APPROX. 65-70 DEGREES. FOR MAGIC SWING REFER TO INHIBIT SWITCH BEA PT# 10 SSINHL OR 10SSINHR.

2 ) THE BODYGUARD RELAY OUTPUT FUNCTION MUST BE CHANGED TO #2.
3 ) SHOWN LH,RH MAGIC SWING AND RH MAGIC FORCE FOR LH MAGIC FORCE REVERSE RED AND BLACK WIRES.

4 ) DOOR CONTROL SW2 SWITCH BANK SET DIPSWITCH # 1 & 3 TO THE OFF (TIMER) POSITION.

5 ) JUMPER 6 & 8.
6 ) INSTALL BLUE WIRE INTO PIN 6. INSTALL WHITE WIRE INTO PIN 1

LEFT APPRCH SIDE SSCAN

RIGHT APPRCH SIDE SSCAN

EAGLE

N.C. 5

N.O. 4
green
COM 3
white
POWER 2
black
POWER 1
red

TITLE: STANLEY MP CONTROL WITH LO-21P

PARALLAX II SYSTEM Q-DISCONNECT
ON SAFETY SIDE

80.0188.04

RIGHT SAFETY SIDE SSCAN

LEFT SAFETY SIDE SSCAN

BODYGUARD

RED

GREEN

OFF

ON

LO21 P

GREEN

BLUE

HOLD OPEN

AUTO

OFF

24 V

TRANSFORMER

SUPERSCAN QUICK

DISCONNECT CABLE

SUPERSCAN QUICK
DISCONNECT CABLE

Common
N/O

N/C

MAGIC FORCE
AUXILLARY SWITCH 4
(SEE NOTE # 1)

1 COMMON

2 OPERATE

3 SENSOR OP

4 12 VAC

5 12 VAC

6 AUX INPUT

7 SAFETY/STALL

8 COMMON

INSTALL JUMPER
IF NO BREAKOUT
SWITCH.

BLACK -

BLACK

WHITE

YELLOW

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME

AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE
ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER

SACRIFICE THE SAFE OPERATION OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM

Advertising