Belkin F6H650-SER User Manual

Belkin Tools

Advertising
background image

INTRODUCTION

Thank you for purchasing a Belkin Uninterruptible Power Supply
(UPS). Each year, several natural and man made occurrences put
the power supplied to your work stations in your home or office in
jeopardy. At risk is your hardware, software and data because of
these power problems.

IMPORTANT!

Please save this manual!
It contains important operating instructions and warranty information
pertaining to your UPS.

Please save or recycle the packaging materials!
The UPS packaging was designed to provide protection during
shipment and delivery. This packaging can be reused should you
have return the UPS for service. Damage sustained during transit is
not covered under the warranty.

Federal Communications Commission Interference Statement

This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. To assure continued
compliance, use only shielded interface cables when connecting to
computer or peripheral devices. Any changes or modifications not
expressly approved by the party responsible for compliance could
void the user’s authority to operate this equipment.

CONTENTS

You should have received the following:
1 – UPS unit
1 – Sentry Bulldog Shutdown Software
1 – Serial Cable
1 – USB Cable
1 – Phone Line Cable

UPS FEATURES AND FUNCTIONS

Before installation, please inspect the UPS upon receipt. Make sure
that nothing is damaged.

Your UPS features 3 LED indicators. Each is marked by a power
icon, please familiarize yourself with this chart as it will assist you in
the use of your UPS.

Chart 1






Front Panel

Diagram 1

1.

UPS Outlets (See #1 on Diagram 1)

These outlets are your battery back up outlets. We strongly

recommend that only sensitive equipment such as your computer

and monitor should be plugged into these outlets. Never plug in any
printer.

Should a power outage occur, your battery backup will automatically

turn on. Power (utility or battery) is not supplied to these outlets when

the UPS is switched off.

Please do not plug any surge protectors or power strips into the

battery back-up outlets (i.e. daisy chaining).

2.

SURGE Protected outlets (See #2 on Diagram 1)

These outlets do not provide power during a power outage.

Equipment such as computer peripherals, printers, fax machine’s, or

a desk lamp may be plugged into these outlets. These outlets are not

controlled by the On/Off button.

3. The On/Off button has 3 functions:

1. Turns on the UPS. Depress button at least 2

seconds. The green light will come on.


2. Cold Start function. Assuming the battery is

charged the UPS will work without it being
plugged into an outlet. Depress and hold the key
for at least 2 seconds to turn on the UPS. The


3. Silence function. During “On Battery Mode”, the

audible sound can be turned “ON” or “OFF” by
depressing the switch.


Side Panel A

AC Input

Circuit Breaker

IN

Push to Reset

Refer to Bottom for

Cautionary Markings

Phone/Fax

Modem

Protection

OUT

OUT

1

2

3

Diagram 2

4. AC Input Power Cord (See #1 on Diagram 2)

Provides power to your UPS.


5. Phone/ Fax/ Modem Surge Protection (See #2 on Diagram 2)

The Phone/ Fax/Modem lines are surge protected. There is one input
jack and two output jacks.

6. AC Breaker (Circuit Breaker; See #3 on Diagram 2)

Should a power overload occur, the circuit breaker will trigger the
UPS to turn off AC power.

Side Panel B

Diagram 3

7.

Your UPS features a serial communication port. Installation of the
cable and software is optional. This allows the UPS to connect to you
computer. The Sentry Bulldog Software will not work if the UPS is not
connected to you computer. This does not mean the battery backup
feature will not work without the software and cable installed. The
UPS will still provide backup power but you will be unable to utilize
the data management capabilities of the software.

UPS INSTALLATION

1. Please plug in your UPS without any equipment

plugged in.

2. Turn on your UPS by depressing the On/Off button

for approximately 2 seconds. You will see the

green indicator light come on. We recommend you

charge the battery for at least 8 hours prior to full

use. The battery will not charge unless the UPS is

turned on.

Should you see the red battery light come on, the

battery may need charging.

Should the red site wiring fault light come on.

Please refer to the UPS Features and Functions

(Chart 1) for the proper reference.

3. Turn off the UPS before installing any products into the UPS or

Surge outlets. Please be sure all equipment to be installed into

any of the outlets is turned off. This will ensure that a power

disturbance will not affect your equipment.

4.

Plug in only one computer and monitor into the UPS outlets. We

strongly recommend that only this equipment be plugged into

the UPS outlets. For all other equipment, plug into the Surge

outlets.

5. Plug one end of the phone cable you received into your

telephone jack and plug the other end into the jack marked IN.
You may now plug a phone, fax or modem into the two jacks
marked OUT. (See Diagram 3)

Phone

Modem

/ Fax

To Telephone Socket

Diagram 4

6.

(Optional) To full utilize the Sentry Bulldog Shutdown Software,
you will need to connect the UPS to your computer. Connect the
RJ45 jack to your UPS then connect the serial end to the serial
port on your computer.

SOFTWARE INSTALLATION

(Optional)


1. Your UPS features the Sentry Bulldog Shutdown Software.

This allows protects and saves your data should a power
outage occur.


2. To install the software, please place the CD into the CD player

of your computer.


3. Your computer should automatically run the CD. If this does not

occur, goto the Run feature on your Start icon (lower left corner)
on your screen. Please enter the CD drive, it may be D:. Should
you continue to have a problem, please refer to your computer’s
owner’s manual for the correct drive.


4. Once uploaded, please click the Bulldog icon on the screen.

5.

Click Install Belkin Sentry Bulldog for Win
95/98/ME/NT4/2000/XP


6.

InstallShield Wizard will appear onscreen, click Next.


7. Please read the License Agreement and click Yes.

8. On Setup Type, click ALL (Standalone). You should not install

the networking files unless you technically qualified to use these
features.


9. On Choose Destination, click Next.

10. On Select Program Folder, click Next

11. On Setup Type, please choose your language choice.

12. The software will now upload. Once completed, please click

Finish.


13. Please click the appropriate user’s manual to download.

14. Click X on the Bulldog setup screen to leave the software setup.

15. Please refer to the user’s manual for software setup and

information on software features.

Uninstall for Windows 95/98/Me/NT4/2000/XP

There are two options to uninstall the Sentry Belkin Shutdown Software.

1.

Select the Setup from the BELKIN SENTRY BULLDOG program
folder and select the remove option to begin the uninstall
procedure.


2. Select Add/Remove Programs from the Control Panel and click on

the BELKIN SENTRY BULLDOG item then press the
Add/Remove button.

TECHNICAL SPECIFICATIONS

MODEL

F6H500-USB

RATED

CAPACITY

500VA /300W

RATED

VOLTAGE

105-135Vac

INPUT

PHASE /

FREQUENCY

Single phase 60HZ

VOLTAGE

Step wave

OUTPUT

FREQUENCY

60HZ (±1HZ)

BACK UP

TIME

Desktop computer +17” monitor≧

13mm

BATTERY

RECHARGE

TIME

8hours to 90%

TEMPERATU

RE

0~35℃

ENVIRONMEN

T

HUMIDITY 10~90%

SAFETY UL1778

/

C-UL

EMI

FCC CLASS B

SAFETY

REGULATION

EMS

IEEE C62.41 CATEGORY A

DIMENSION

3.14 X 9.84 X 6.6 inches

APPEARANCE

NET WEIGHT

4.6KGS/

10.14LBS

All specifications are subject to change without prior notice.

Indicator LED

Indication

Description


ON-LINE

О Solid green

AC power is on








ON-BATTERY
and
LOW-BATTERY

☼ Flashing Red

The On-Battery and

Low-Battery LED can

indicate 1 of 3 conditions:

1. The UPS is on battery

backup if the green light

is off and an intermittent

audible alarm is on. The

UPS will begin

shutdown procedure.

2. Battery is low. The UPS

will start shutdown. The

buzzer sounds an

audible alarm.

3. There is a problem with

the UPS. The LED will

be lit continuously and

the buzzer will sound

audible alarm for 10

sec.



SITE WIRING

FAULT


О Solid Red

The Site Wiring fault LED
can indicate 1 of 2 possible
conditions:
1. Open or high resistance

ground

2. Hot or neutral polarity

circuit

F6H350-SER
F6H500-SER
F6H650-SER
F6H500-USB

R

2

22

2

1

11

1

3

33

3

Serial Communication Port

Battery Light

Site Wiring Light

Advertising
This manual is related to the following products: