2 technical specifications dsa-n2b20, Technical specifications dsa-n2b20 – Bosch DSDA ISCSI DISK ARRAY SERIES DSA-S5B50 User Manual

Page 34

Advertising
background image

32

en | Technical Data

DSDA iSCSI Disk Array Series

V 1 | 2008.08

Installation Guide

Bosch Security Systems

8.2

Technical Specifications DSA-N2B20

8.2.1

Electrical Requirements – One Controller Module

8.2.2

System Hardware Specifications

8.2.3

Mechanical

8.2.4

Space Requirements

8.2.5

Environmental

Input voltage: 100 to 120V

Worst case,

single PSU

System,

two PSUs

• input current measured

3.37 A

3.22 A

• input power measured

332 W

316 W

• thermal dissipation

1133 BTU/hr

1077 BTU/hr

Input voltage: 200 to 240V

Worst case,

single PSU

System,

two PSUs

• input current measured

1.69 A

1.66 A

• input power measured

327 W

305 W

• thermal dissipation

1114 BTU/hr

1039 BTU/hr

Input power frequency

50 to 60 Hz

50 to 60 Hz

Chassis

2U, 19” rack-mountable

Power supplies

Dual redundant, hot pluggable

Max disk drives

12 x 750 GB SATA II drives

Max raw Capacity

9 TB

DDR2 memory (System RAM)

1024 MB

Nonvolatile SDRAM (NVRAM)

256 MB - protects “in flight” transactions

for 3 days in the event of a power loss.

Integrated I/O

2 Ethernet 10/100/1000 Copper

Remote management (via LAN)

Yes

Dimensions (H x W x D)

89 x 447 x 572 mm

(3.5 x 17.6 x 22.5 in)

Weight

27.215 kg (60 lb) full

Front–cooling

152 mm (6 in)

Rear–cooling

305 mm (12 in)

Front of chassis–maintenance

762 mm (30 in)

Rear of chassis–maintenance

915 mm (36 in)

Operating temperature

+10 °C to +40 °C (+50 °F to +104 °F)

Nonoperating temperature

-40 °C to +60 °C (-40 °F to +140 °F)

Relative humidity

20 to 80% noncondensing

Acoustic level

N/A