Trouble shooting guide for model #sp1 jet cooker – Bayou Classic SP10 User Manual

Page 33

Advertising
background image

TROUBLE SHOOTING GUIDE FOR Model #SP1 Jet Cooker

SYMPTOM

Burner will not light
and burner tube is clean

Not enough gas flow from
propane tank

Open propane tank valve all
the way

CAUSE

POSSIBLE SOLUTION

Low gas level in propane tank,
or tank is empty

Check gas level in propane tank,
re-fill or exchange tank

Faulty regulator hose assembly

Contact 1-800-864-6194;
Model M5HPR-1

Hissing or gurgling sounds
coming through gas train
from tank to burner

Damaged hose

Perform soapy water test to check
for cracks in hose.
See pages 13-14; Model M5HPR-1

Gas leak

Perform soapy water test to check
all connections - See pages 13-14

Flame has gone out

Low gas level in propane tank,
or tank is empty

Check gas level in propane tank

Too much wind

Check wind direction and set
cooker away from windy areas

Blockage in jet tube

Clean and check burner for
spiders, insect nests and debris

Cooker lights but the flame
remains very small
Repeated from page 22

Rapid gas flow from propane
tank activates EXCESS FLOW
safety device

Repeat lighting instructions and
be certain to S-L-O-W-L-Y open
cylinder valve one full turn, then
S-L-O-W-L-Y open regulator valve
to light cooker

Cooker will not light
Repeated from page 22

Orifice Hole in Jet Tube is not
facing straight up

Using a wrench, turn brass cap
until orifice hole is facing up

Do not use this appliance if gas
leaks cannot be stopped and
corrected.

Orifice hole is blocked

Using a wire, insert into orifice
hole to remove blockage debris

31

Advertising
This manual is related to the following products:

SP1