Figure 7 Ventilation Air From Outdoors

WARNING

THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR
FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO
ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES
IN YOUR HOME.

VENTILATION AIR FROM OUTDOORS


Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent
openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly
to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code
NFPA 54/ANSI Z223.1, Section 4.3, “Air For Combustion and Ventilation” for required size of
ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet air into attic if attic has a thermostat-controlled
power vent. Heated air entering the attic will activate the power unit.

Ventilated Attic

Outlet Air

Inlet Air

Ventilated

Crawl Space

To

Crawl

Space

To Attic

Outlet Air

Inlet Air