Bounty Hunter LEGACY 3300 User Manual

Page 23

Advertising
background image

23

2

TABLE OF CONTENTS

Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5

Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Quick-Start Demo . . . . . . . . . . . . . . . . . . . . . .7-8

Basic Operation . . . . . . . . . . . . . . . . . . . . . .9-12

All Metal . . . . . . . . . . . . . . . . . . . . . . . . . .10

Discrimination . . . . . . . . . . . . . . . . . . . . . .10

Notch . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Zap . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-12

Pinpoint . . . . . . . . . . . . . . . . . . . . . . . . . .12

Audio Target Identification . . . . . . . . . . . . . . .13

Target and Depth Display . . . . . . . . . . . . . .14-15

Sensitivity Adjustment . . . . . . . . . . . . . . . . . . .16

In The Field Techniques . . . . . . . . . . . . . . .17-22

Ground Balancing . . . . . . . . . . . . . . . . . . . . . . .20

Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . .23

Treasure Hunter’s Code of Ethics . . . .Back Cover
Warranty
. . . . . . . . . . . . . . . . . . . . . . .Back Cover

TROUBLE SHOOTING GUIDE

SYMPTOM

CAUSE

SOLUTION

Detector chatters

• Using detector

• Use detector

or beeps erratically

indoors

outdoors only

• Using detector near • Move away

power lines

from power lines

• Using 2 detectors in • Keep 2 detectors

close proximity

at least 20’ apart

• Environmental

• Reduce sensitivity

electromagnetic

until erratic

interference

signals cease

Constant low tone

• Discharged batteries • Replace batteries

or constant repeating
tones

• Wrong type of

• Use only 9V

batteries

alkaline batteries

LCD does not lock

• Multiple targets

• Move coil slowly

on to one target ID

present

at different angles

or detector emits

• Highly oxidized

multiple tones

target

• Sensitivity set

• Reduce sensitivity

too high

No power, no

• Dead batteries

• Replace batteries

sounds

• Poor battery

• Push batteries in

contact

tighter

• Insert paper spacers

(see page 6)

• Pry back

battery clips

• Cord not connected

securely

• Check connections

Detector sounds

• Ground Balance

• Move Ground

continuous tone in

over-adjusted

Balance knob

Pinpoint Mode when

counter-clockwise

coil is lifted away
from ground.

Detector sounds con- • Detector needs to be • Press Pinpoint
tinuous tone with

retuned

• Re-ground balance

coil over ground

False high tones

• Ground Balance out

• Rotate GB knob

of adjustment

counterclockwise

TROUBLE SHOOTING