Replace lightbulb, Replace drive belt replacement belts, Replacement bulb – Bissell 3512-5 User Manual

Page 8

Advertising
background image

8

Replace Drive Belt

Replacement Belts

Use only BISSELL

®

Replacement Belt Style 2

(#3215P) in your Upright Vacuum Cleaner. You
may purchase these belts from your retailer.
To locate a retailer near you, or to place an order
using Visa, MasterCard, cheque or money order
call:

BISSELL Customer Service

1-800-263-2535

Monday - Friday
8:00 A.M. - 4:30 P.M. (E.S.T.)
E-mail us at: [email protected]
Or visit our Web Site @ www.bissell.com

1. With Rotating Floor Brush removed from vacuum cleaner,

stretch old belt to clear Motor Pulley, and remove belt.
Discard.

2. Place new Drive Belt over Motor Pulley and stretch other

end over crown of Rotating Floor Brush.

3. Place belt end of Rotating Floor Brush into its slot and hold

it in place with your left hand, while slowly pulling opposite
end of brush down into its slot with your right hand.

4. Turn Rotating Brush by hand several times in direction of

Motor Pulley. If properly installed, Drive Belt will centre itself
on Rotating Brush crown.

5. Position Brush Cover Tabs in the four Brush Cover slots

along front of Powerfoot, and snap Brush Cover into place.

Replace Lightbulb

1. Unplug unit from electrical outlet.
2. Remove Cleaning Selector and Floor Surface Selector

from Top Cover by grasping Selectors firmly and pulling
straight up.

3. Place Handle in Upright position and turn vacuum cleaner

face down on floor.

4. Insert a blade type screwdriver into four slots on underside

of Powerfoot and pry outward on sides of Top Cover to
unsnap internal latches.

5. Return vacuum cleaner to Upright position on floor and

push Handle Release Pedal with foot to lower the Handle
to Low Cleaning Position.

6. Lift Top cover from Powerfoot (If Vacuum Hose is attached

to Hose Port, remove by turning counterclockwise and
lifting up).

7. Gently work bulb from side to side while pulling up. Do

not squeeze bulb too firmly with fingers or it may break
and injure you.

8. Insert new bulb, pushing gently until it is firmly seated

in socket.

9. Realign Top Cover to Powerfoot, making sure opening

under Tool Door fits over Hose Port. Press Top Cover
downward until you hear all four internal latches snap
into place.
Test Top Cover for tightness by pulling up on it.

10. Replace Cleaning Selector and Floor Surface Selector by

pushing them on firmly.

Replacement Bulb

Use only BISSELL

®

Replacement Bulb (555-9069)

in your Upright Vacuum Cleaner. You may
purchase theses bulbs by calling

BISSELL Customer Service

1-800-263-2535

Monday - Friday
8:00 A.M. - 4:30 P.M. (E.S.T.)
E-mail us at: [email protected]
Or visit our Web Site @ www.bissell.com

Advertising