2appliance details – Bosch PROTANKLESS GWH 345/450 ESR User Manual

Page 4

Advertising
background image

6 720 607 909

4

Appliance details

2

Appliance details

2.1

Features

Parts

• Sealed combustion burner.

Safety

• Ionization flame sensor

• Over temperature protection.

High quality materials for long working life

• Copper heat exchanger

• Compact space saver: mounts on a wall with

supplied bracket.

Features

• LCD screen to display temperatures, burner

operation and error codes

• On/Off button and separate temperature controls for

domestic water heating and recirculating water

• Reset button

• Failure codes for diagnostics and repair

• Freeze prevention cycle.

2.2

GWH-345/450-ESR Specifications
(Technical data)

Approved in US/Canada

Capacity

GWH345 Maximum flow rate: 3.5 GPM (13 l/min) at a
45°F (25°C) rise.
GWH450 Maximum flow rate: 4.5 GPM (17 l/min) at a
45°F (25°C) rise.

Maximum output

GWH345 - 77,900 Btu/h (22.8 kW)
GWH450 - 98,400 Btu/h (28.8 kW)

Maximum input

GWH345 - 95,000 Btu/h (27.8 kW)
GWH450 - 120,000 Btu/h (35.1 kW)

Efficiency in %

GWH345 Combustion efficiency: 82%
GWH450 Combustion efficiency: 81%

Min. Output

GWH345 - 23,900 Btu/h (7 kW)
GWH450 - 35,500 Btu/h (10.4 kW)

Temperature Control

Selection range: 115°F (45°C) - 190°F (90°C)

Gas Requirement

Gas connection (inches) - ¾”

Inlet gas pressure under operation (with a high hot
water flow rate)*

• Propane: 11” - 14” water column

• Natural Gas: 5.5” - 8” water column.

* To measure gas pressure, see Measuring Gas
Pressure, chapter 3.8.

Venting

3" AL 29-4C single wall sealed stainless steel vent
pipe.
See chapter 3.6 for Venting.

Water

• Hot water connection - ¾” NPT

• Cold water connection - ¾” NPT.

Combustion

• NOx ≤ 100 ppm

• CO ≤ 250 ppm

• CO

2

level (see table 8 for correct restrictor

dimension).

Dimensions

• Depth (in): 11 ¾” (300 mm)

• Width (in): 15 ¾” (400 mm)

• Height (in): 27 ½” (700 mm)

• Weight: 47 pounds (21 kg).

Gas types

Natural Gas.
Liquid Propane.
The appliance is not field convertible.

Voltage

120 V AC (50/60 Hz)

Amperage

Idle - 40 mA
Operation - ≤ 1.5 A

Noise
≤ 50 db (A)

Safety devices

• Flame failure device (Ionization flame control)

• Overheat prevention (temperature limiter)

• Pressure switch (blocked vent protection).

i

BOSCH is constantly improving its
products, therefore specifications are
subject to change without prior notice.

Advertising