Bakers Pride BCO-G1 User Manual

Page 2

Advertising
background image

BAKERS

PRIDE

Continuous product improvement is a policy of Bakers Pride Oven Company.

Therefore, specifications and design are subject to change without notification

TS: 3M 11/04

BAKERS PRIDE OVEN COMPANY, INC.

30 Pine Street, New Rochelle, NY 10801

914/576-0200 • 1-800-431-2745 • fax 914/576-0605

www.bakerspride.com

SHIPPING INFORMATION

Model

BCO-G1
BCO-G2

565

39.25

43

DOUBLE Shipped in two cartons as per above specifications

Separate gas and electric connections required for stacked ovens

48 ¼

38 ¼

256

1.11

1092

1226

972

Shipping Weight

Carton Size

Carton Dimensions

Lbs.

Cubic Feet

Inches

Width

Depth

Height

Inches

Inches

Kilos

Cubic Meters

mm

mm

mm

MINIMUM CLEARANCES

Suitable for installation on combustible floors when

installed on factory supplied legs or casters

Right
Left
Rear

1
1
3

1
3
3

25
25
76

25
76
76

Inches

Inches

Vent Hood

Direct Venting

mm

mm

ALL DIMENSIONS NOMINAL

FRONT VIEW

SIDE VIEW

Single Unit

FRONT VIEW

Double Unit

72 1/4"

(1835mm)

41 9/16"

(1056mm)

8 1/4"

(210mm)

39"

(991mm)

29" (737mm)

interior

39"

(991mm)

32"

(813mm)

SIDE VIEW

20"

508mm

22 1/4"

567mm

63 3/8"

(1610mm)

31 3/8"

(797mm)

POWER SUPPLY

Model

BCO-G1

60,000

17.58

60

3.5

2

1

900

1,725

120

BTUH

HZ

Amps

Wire

RPM-low

KW

Voltage 1O/

Phase

RPM-high

Separate gas connections or external manifold required for stacked ovens

GAS SUPPLY

— 1/2” NPT rear connection

Gas Type

Natural
Propane

3.5"

10"

7"

11"

9 min

25 max

17.5 min
27.0 min

WC

WC

Manifold Pressure

Inlet Pressure

Mbar

Mbar

NOTE:

NOTE:

Legs with adjustable

bullet feet are 27 5/8" tall

(702mm)

minimum

Legs with

adjustable

bullet feet

are 4 1/2"

(140mm)

minimum

and

6”

(152mm)

maximum

Advertising