Bunn FMD-1 FMD-2 User Manual

Page 9

Advertising
background image

9

TROUBLESHOOTING (cont.)

PROBLEM
Product will not dispense (cont.)

Water is not hot

PROBABLE CAUSE
5. Solenoid Valve (Inlet)

6. A) Level Control Board and Probe
- FMD-1

B) Control Board and Probe - FMD-
2

7. A) Auger Drive - FMD-1

B) Auger Drive - FMD-2

8. Water Strainer

9. Lime build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate corro-
sive reactions resulting in serious
leaks.

10. Transformer - FMD-2

1. Limit Thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat. Use only BOM
replacement part #29329.1000

2. Control Thermostat

3. Tank Heater

REMEDY
Refer to

Service

- Solenoid Valve

(Inlet) for testing procedures. See
page 36

Refer to

Service

- Level Control Board

and Probe for testing procedures.
See page 30

Refer to

Service

- Control Board and

Probe for testing procedures. See
page 20

Refer to

Service

- Auger Drive. See

page 13

Refer to

Service -

Auger Drive. See

Page 15

(A) Direction of flow arrow must be
pointing towards dispenser.

(B) Remove the strainer and check
for obstructions. Clear or replace.

Inspect the tank assembly for exces-
sive lime deposits. Delime as re-
quired.

Refer to

Service

- Transformer for

testing procedures. See page 39

Refer to

Service

- Limit Thermostat

for testing procedures. See page 32

Refer to

Service

- Control Thermo-

stat for testing procedures. See page
19

Refer to

Service

- Tank Heater for

testing procedures. See page 37

29112 051200

Advertising