7

FIBER LINK

Control Data Signal

Data Directions

—Control: RX→TX; Response: TX→RX

Data Formats

—All major up-the-coax formats, including American Dynamics,

Baxall, Burle, Elbex (sync and control), Panasonic

®

(PTZ and VD2), Pelco™,

Robot, Sensormatic, VCS format, Vicon™, Videoalarm™, and others.

Detection Area

—In even fields, the control signal is imposed on lines 8 through

19. In odd fields, the control signal is imposed on lines 9 through 20.

Pulse Amplitude

—50 mV to 2 V

Genlock Sync Signal

Sync Direction

—RX→TX

Detection Area

—Can be imposed on all lines outside the control area

Sync Amplitude

—Up to 6 V

Optical

Wavelength

—850 and/or 1300 nm

Optical Mode

—Multimode

Optical Budget

—13 dB minimum

Operating Distance at 850 nm

—Operating distance is approximate, and will be

affected by the type and number of splices in the fiber and by the exact type of
fiber used. Maximum: 10,000 ft. (3048 m)

Emitter Type

—LED

Fiber Size

—62.5 µ

Modulation Type

—Frequency modulation

Gain Control

—Fully automatic (AGC)

Transmitter Launch Power

—> -17 dBm (1300 nm)

Transmitter Sensitivity

—< -27 dBm (850 nm)

Receiver Sensitivity

—< -26 dBm (1300 nm)