Adjustments – Blanco BCGC74 - BCGC52 User Manual

Page 9

Advertising
background image

9

Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.

8) TAPS

Our taps are suitable for all gas, they are male conical
type.

“Reduced rate” adjustment
- Switch on the burner and turn the relative knob to

the “Reduced rate” position (small flame fig. 1).

- Remove knob “M” (fig. 13) of the tap, which is simply

pressed on to its rod.

- Insert a small screwdriver “D” into hole “C” (fig. 13)

and turn the throttle screw to the right or left until the
burner flame has been adequately regulated to the
“Reduced rate” position.

Check that the flame does not go out when the knob
is sharply switched from the “Full on” to the “Reduced
rate” position.

It is understood that only burners operating with
Natural gas should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with Liquid gas.

ADJUSTMENTS

FIG. 13

Advertising