Service (cont.) – Bunn FMD-4 User Manual

Page 36

Advertising
background image

36

SERVICE (cont.)

FIG. 32 DISPENSE SOLENOID VALVE

TERMINALS

P1672

Removal and Replacement:
1. Remove the four #8-32 screws securing the side

access panel to the housing. Remove panel and
set aside.

2. Remove the wires from the solenoid valve.
3. Turn-off the water supply to the dispenser.
4. Using the tank drain tube, drain enough water

from the tank so the water level is below the
dispense valve mounting hole.

5. Disconnect the water line from the solenoid valve.
6. Remove the #8-32 keps nut securing the solenoid

valve bracket to side of the tank. Remove solenoid
valve.

7. Install new solenoid valve and o-ring on side of the

tank and secure in place with valve mounting
bracket and #8-32 keps nut.

8. Push the water line onto the tube on bottom of

solenoid valve.

9. Refer to Fig. 32 and reconnect the wires.
10. Reinstall side access panels.

SOLENOID VALVE (DISPENSE) - FMD-4 & FMD-5
(cont.)

WHIto Main Harness

TAN to Main Harness Station #1
RED to Main Harness Station #2
ORN to Main Harness Station #3
YEL to Main Harness Station #4
BLU to Main Harness Station #5

35135 012103

Advertising