Low temperature -45 °C chest freezers

Low temperature -45 °C
chest freezers

T

he low temperature -45 °C chest freezers are designed to meet

the specifi c requirements of an array of research, industrial or

clinical applications. Where there is a need to store products or

samples at lower than usual freezing temperatures freezers are the

ideal solution. Offering supreme temperature stability as well as

temperature uniformity within the units, they ensure the safe, cold

storage of specimens, biological samples and other substances.

The low temperature chest freezers are available in three sizes and

are equipped with a precision digital controller, which guarantees

maximum temperature accuracy. Having a volt-free contact and an

RS 485 serial interface, Liebherr’s low temperature chest freezers can

also be connected to a central alarm and documentation system,

which provides additional safety for the samples within the unit.

22-23_LaborSpecial_EN.indd 22

17.02.14 11:38

The Comfort electronic controller

The precision Comfort electronic controller with digital temperature display enables temperatures to be

set accurately. Symbols indicate the operating status of the appliance at all times. To satisfy laboratory

hygiene requirements, the Comfort electronic controller has an easy-clean membrane keypad.

External temperature and alarm connections

The low temperature chest freezers with Comfort electronic controllers are equipped with a volt-free

contact for alarm forwarding to an external remote warning system. In addition, the appliances have

an RS 485 serial interface for central documentation of the temperature profi le data and alarm events.

Integrated alarm systems

A visual and audible temperature alarm alerts the user if temperature deviation limits are exceeded. The

parameters for the temperature alarm can be individually set. In addition, a visual and audible alarm

is activated when the lid is open for longer than 1 minute. The door-open alarm delay can be adjusted

between 1 and 5 minutes. Furthermore, the laboratory appliances with Comfort electronic controllers

have a visual power failure alarm when mains power returns and a sensor defect alarm.

Integrated data memory with min/max temperatures

The Comfort electronic controller has an integrated data memory. It logs the maximum and minimum

internal temperatures that occurred once the set temperature was reached, the last three temperature

alarms and power failures, together with the time, date and duration of the alarm. The respective data

can be recalled using the AlarmLog function and read on the display panel.

1-point calibration

The low temperature chest freezers with Comfort electronic controllers provide 1-point calibration for

accurate temperature control. This permits compensation between the set temperature and the actual

internal temperature. Positive or negative changes to the correction value can be made in steps of 0.1K.

StopFrost-System

The Stop-Frost system fi tted to the LGT models has 2 major advantages: frosting of the freezer and its
contents is signifi cantly reduced. This means the time-consuming process of defrosting is necessary far
less often. The vacuum is also equalised quickly after the lid has been opened and closed and the chest

freezer can be re-opened effortlessly.

Lid handle

The aluminium lid handle of the LGT models is simple and tough for intensive commercial use. All
models have locks as standard.