Alarm messages, Alarm test, Audible warning signal settings – Liebherr MKUv 1610 User Manual

Page 7

Advertising
background image

19

GB

Alarm messages

1. LED

flashes

If

appears in the display, the appliance has a fault.

Consult your nearest customer service point.

2. LED

flashes and

appears in the display

The power failure alarm battery is supplying too low a voltage

or is defective.
Consult your nearest customer service point.

3. LED

flashes, the display reads

HI

or

LO

The interior is too warm (HI) or too cold (LO).
The audible warning signal sounds.

4. HACCP flashes - the current interior temperature,

and

are displayed alternately

There has been a power cut of some length or the interior was

too warm or too cold during a certain period of time.
Up to three alarm events can be stored and called up.

Alarm test

This test checks the function of the internal and any external

connected alarm device.

The appliance does not stop its refrigerating function during

this test.

Activating the test

Press

+

for 5 seconds.

• The display will change to a temperature value of 0.2°C below

the set upper alarm limit.

• The temperature value will now rise by 0.1°C every 2 seconds.

• When the upper alarm limit is reached,

will appear in the

display. An external alarm unit connected to the floating alarm
output will now be activated.

• The temperature value will continue to rise up to 0.2°C above

the upper alarm limit.

• The same process will take place automatically for the lower

alarm limit.

will appear in the display.

The LED

will be lit during the test.

The electronic control system will automatically switch back to

normal operating mode.

Cancelling the test prematurely
Press

for 5 seconds.

Audible warning signal settings

The audible warning signal will be muted for the current alarm

after the button

has been pressed.

Complete the following steps if you want the audible warning

signal to reactivate automatically.

Press

for 5 seconds. Display =

Display =

Display =

Display =

Display =

Display =

Display =

Display =

Display =

Automatic reactivation of the audible warning signal is now active.

The time before the audible warning signal sounds again must be set.

Display =

Display = Time in minutes after which the audible

warning signal will sound again after the
button

has been pressed. Setting

range = 1 - 120 minutes.

Use buttons

and

to select the desired setting.

Display =

Press

for 5 seconds.

The electronic control system will switch back to normal operat-

ing mode.