Operating and control elements

1

Temperature display

2

Temperature setting buttons

3

Audible warning On/Off button

4

Child lock activated symbol

5

On/off button

6

Fan button

Setting the temperature

Increasing the temperature

Press the Up button.

Reducing the temperature

Press the Down button.

- When pressing one of the buttons for the first time, the display

will start to flash.

- Pressing this button again enables you to change the temperature

setting.

- The electronic controls will switch over automatically about

5 seconds after the last time you pressed the button, and the

actual temperature will be displayed.

Storing wine

If you are storing wine for long periods of time, it should be stored

at a temperature of between 10°C and 14°C.
This is the temperature wine cellars are kept at, and it is just right

to allow wine to mature properly.
The following drinking temperatures are recommended for the

various types of wine.
Red wines: +14°C to +18°C

Rosé wines: +10°C to +12°C

White wines: +8°C to +12°C

Sparkling wines, Prosecco: +7°C to +9°C

Champagne: +5°C to +7°C

Switching the appliance on and off

Switching the appliance on

Press the On/Off button until the temperature display

lights up.

Switching the appliance off

Keep the On/Off button pressed for approx. 3 seconds so that

the temperature display goes out.

Setting up

• Avoid positioning the appliance in direct sunlight or near cookers,

radiators and similar sources of heat.

• The floor on which the appliance stands should be horizontal

and level.Compensate for uneven floors with the adjustable feet.

Do not cover ventilation openings

or grille.

• Standard EN 378 specifies that the room in which

you install your appliance must have a volume

of 1 m

3

per 8 g of R 600a refrigerant used in

the appliance, so as to avoid the formation of

inflammable gas/air mixtures in the room where

the appliance is located in the event of a leak in

the refrigerant circuit. The quantity of refrigerant

used in your appliance is indicated on the type

plate on the inside of the appliance.

• Always install the appliance directly against the wall.

• Place the appliance in its final position

at the place of installation.

Extend the adjustable foot at the bottom

hinge bracket until it rests on the floor

and then make a further 90° turn.

Dimensions

WKt 4551 A = 1650 mm

WKt 5551 A = 1920 mm

Electrical connection

Only operate the appliance with alternating current (AC).

The permissible voltage and frequency are indicated on the type

plate. The position of the type plate is shown in the section entitled

Description of the appliance.

The socket must be properly earthed and protected by a fuse.

The tripping current of the fuse must be between 10 A and 16 A.

The socket must not be situated behind the appli-

ance and must be easily accessible.

Do not connect the appliance using an exten-

sion cable or extension socket.
Do not use stand-alone inverters (conversion

of direct current to alternating current/three-

phase current) or energy-saving plugs. Risk

of damage to the electronic control system!