2

LR 1200 ANSI/ASME B 30.5

Dimensions

Basic machine with undercarriage

28´7´´

12´3´´

24´8´´

59´´

11´6´´

31´10´´

27´1´´

63´´

15´1´´

63´

47.2´´

23´

19´10´´

20.5´´

53

´´

R 28´7´´

9´10´´

47.2´´

19´

24´11´´

R 20´4´´

narrow track width

Operating weight

The operating weight includes the basic machine with crawlers,

2 main winches 26,980 lbf including wire ropes (853

ft and

1624 ft) and 66 ft main boom, consisting of A-frame, boom foot
(33 ft), boom head (23 ft) and boom extension (10 ft), 181,440 lbs
basic counterweight, 79,400

lbs carbody counterweight and

551,200 lbs hook block.

Total weight

approx. 462,970 lbs

Ground pressure

Ground bearing pressure

16.5 PSI

Equipment

Main boom

(No. 2320.xx)

max. length

292 ft

High reach

(No. 2320.xx and 1916.xx)

384 ft

Luffing jib

(No. 1916.xx)

max. length

312 ft

Max. combination

main boom 174 ft

luffing jib 312 ft

Fixed jib

(No. 1008.xx)

36 ft

85 ft

Auxiliary jib 53,000 lbs (option 79,400 lbs)

Remarks

1.

The lifting capacities stated are valid for lifting operation only
(corresponding with crane classification according to F.E.M.
1.001. crane group A1).

2.

Crane standing on firm, horizontal ground.

3.

The weight of the lifting device (hoisting ropes, hook block,
shackle etc.) must be deducted form the gross lifting capacity to
obtain a net lifting value.

4.

Additional equipment on boom (e.g. boom walkways, auxiliary jib)
must be deducted to get the net lifting capacity.

5.

For max. wind speed please refer to lift chart in operator‘s cab
or manual.

6.

Working radii are measured from center of swing and under load.

7.

The lifting capacities are valid for 360 degrees of swing.