8decommissioning, 1switching off the appliance, 2taking the appliance out of service – Liebherr CTPsl 2521 Comfort User Manual

Page 11: 9disposing of the appliance, 8 decommissioning, 9 disposing of the appliance, Decommissioning, 1 switching off the appliance, 2 taking the appliance out of service

Advertising
background image

The temperature is not cold enough.

The door of the appliance is not properly closed.

u

Close the door of the appliance.

Insufficient ventilation.

u

Clear ventilation grilles.

The ambient temperature is too high.

u

Solution: (see 1.2) .

The appliance was opened too frequently or for too long.

u

Wait to see whether the appliance reaches the required

temperature by itself. If not, please contact the after sales

service (see Maintenance).

The appliance is too close to a source of heat (stove, heater

etc).

u

Change the position of the appliance or the source of heat.

The interior light is not on.

The appliance is not switched on.

u

Switch on the appliance.

The illuminant (delivery with LED illuminant) is defective.

WARNING

Risk of injury from LED light!

The light intensity of the LED lighting corresponds to laser

class 1/1M.

If the cover is removed:

u

Do not look directly into the light at close quarters through

optical lenses. Doing so may damage your eyes.

u

Change the lighting (see Maintenance).

8 Decommissioning

8.1 Switching off the appliance

u

Turn temperature control

Fig. 3 (1)

to 0.

8.2 Taking the appliance out of service

u

Empty the appliance.

u

Pull out the power plug.

u

Clean the appliance (see 6.2) .

u

Leave the door open to prevent odour.

9 Disposing of the appliance

The appliance contains some reusable materials

and should be disposed of properly - not simply

with unsorted household refuse. Appliances which

are no longer needed must be disposed of in a

professional and appropriate way, in accordance

with the current local regulations and laws.

When disposing of the appliance, ensure that the refrigeration

circuit is not damaged to prevent uncontrolled escape of the

refrigerant it contains (data on type plate) and oil.

u

Disable the appliance.

u

Pull out the plug.

u

Cut through the connecting cable.

Decommissioning

* Depending on model and options

11

Advertising
This manual is related to the following products: