Step 7 – Check for Leaks

To check for leaks:

• Make 1-2 oz. of leak solution by mixing one part liquid dishwashing

soap and 3 parts water.

• Spoon several drops (or use squirt bottle) of the solution onto the

regulator/canister connections.

• Inspect the connections and look for bubbles

• If NO bubbles appear, the connection is safe.

• If bubbles appear, there is a leak:

• Loosen and re-tighten this connection.

• Re-check for a leak.

• If you continue to see bubbles after several attempts, disconnect

propane source and contact 1-800-762-1142.

Step 8 – Install Access Panel

• Slide top tab of Access Panel inside Shroud Cover.

• Lower bottom of Panel until closed, and rotate Knob until lock flange

rotates inside of slot on plastic ring.

Caution:

Your Endless Summer Portable Heater
has been checked at all factory
connections for leaks. Recheck all
connections, as movement in shipping
can loosen connections. Check for
leaks even if your unit was assembled
for you at the store.