Manual 2100-399
Page 8

FIGURE 3

MOUNTING INSTRUCTIONS

FIGURE 3A

ELECTRIC HEAT CLEARANCE

Side section view of supply air
duct for wall mounted unit
showing 1/4 inch clearance to
combustible surfaces.

MIS-277

MIS-796

NOTE: It is recommended that a bead of silicone

caulking be placed behind the side mounting flanges
and under the top flashing at the time of installation.

WARNING

• A minimum of 1/4 inch clearance must be

maintained between the supply air duct and
combustible materials. This is required for
the first 3 feet of ducting.

• It is important to insure that the 1/4 inch

minimum spacing is maintained at all points.

• Failure to do this could result in overheating

the combustible material and may result in
fire.