power on. System installation screens will automatically appear
and will display the Equipment Summary screen when finished.
The Equipment Summary screen will display REMOTE ACCESS
near the bottom of the screen.

If REMOTE ACCESS is not displayed, check connections to the
ABC wires as well as ensure the Yellow LED is lit on the System
Access Module (this ensures the module has power). The green
LED will be lit next to each ABC connection if the user interface
has established communication.

IX. PIN NUMBER AND SERIAL NUMBER

The PIN and Serial number of the System Access Module are used
by the system owner to register their system with Bryant. Remove
the sticker containing the PIN number from the radio and install at
the front of the Owner’s Guide. Also, write down the SAM serial
number in the Home Owner’s Guide. The serial number can be
found on the SAM packaging, at the bottom of the large SAM
circuit board (see Fig. 3), or in the user interface Service Menu. If
PIN number is lost or missing, it can be found by entering the
Service Menu of the User Interface (10 second press of the
Advance button) and looking at the Model/Serial Numbers screen.
The PIN will be listed with the System Access Module model and
serial numbers.
RS-232 Connector

An RS-232 port has been provided for connection to home
automation equipment. Consult your home automation supplier for
support.

Updating System Profile
The Evolution System will automatically send system information

to Bryant’s computer servers within one hour after the system has

been successfully installed. Access to the system via the internet or

telephone will not be available until this occurs. The system can be

forced to send its information through the following process if

internet and telephone access is required immediately. Press and

hold the RADIO TEST button for 15 seconds. When the button is

first pressed, the red LED will turn on. Five seconds into the press,

the yellow LED will turn on. 15 seconds into the press, the green

COM1 LED will turn on. Release the button when the green LED

turns on. The red LED will flash when messages are being sent.

The red and yellow LED will flash when the SAM is waiting for

message replies. Upon successful profiling, both green LEDs will

be lit. If profiling is not successful, the red LED will be lit solid.

The entire profiling process can take up to 15 minutes per

Evolution System. If two systems are connected to one SAM, then

the profiling process can take up to 30 minutes.
If the Evolution system ABC wiring is moved from connector 1 to

connector 2 (or vice versa), or Evolution equipment has changed,

the System Access Module must update Bryant’s servers with the

new information. This will happen automatically within one hour,

or can be manually forced with the process described above.
TROUBLESHOOTING
FAULT INDICATORS — Under normal operation, the Yellow

and Green LED will be on continuously (solid). If the System

Access Module does not receive communications with the Evolu-

tion system, the Green LED will not be on. If there are faults

present, the Yellow LED indicator will blink a two digit status

code. The first digit will blink at a fast rate, the second at a slow

rate.

STATUS CODE

DESCRIPTION

45

Board Failure

61

Radio out of range (no coverage for five minutes)

62

Loss of communication with the radio

63

Radio not registered with the local network

(unregistered for five minutes)

64

Auxiliary sensor active