Plan the installation, Installation, Page 2 model 744sfl – Broan 744SFL User Manual

Page 2: Mark mounting location, Do not install in a cooking area, Install mounting brackets, Pound in nails

Advertising
background image

Page 2

MODEL 744SFL

PLAN THE INSTALLATION

The unit can be installed anywhere between ceiling joists using

mounting brackets provided. Install in a flat ceiling only.

Typical Installation

Two of the most common ways to

connect ductwork to the unit.

INSTALLATION

2. Mark mounting location.

Position unit between joists and extend mounting brackets.
IMPORTANT: Position brackets so there will be an 1/8” gap
between bottom of housing and ceiling material.
Mark the top
of keyhole slot on all four mounting brackets.

The unit must not be installed above or inside the cooking area shown.

Do not install in a cooking area.

1/8" GAP

1. Install mounting brackets.

Slide the adjustable mounting brackets into the bracket channels
on the housing.
Bend the tabs on the cardboard protector and insert protector
into opening in housing.
NOTE: The cardboard protector shields the inside of the housing
from drywall spray and construction dust. Do not remove it until
after construction is completed.

CARDBOARD PROTECTOR

3. Pound in nails.

Remove unit temporarily, and pound nails partially into joists at
all four marked locations.

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

The unit will operate most quietly and efficiently when located

where the shortest possible duct run and minimum number of

elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce

backdrafts.
Plan to supply the unit with proper line voltage and appropriate

power cable.

ROOF

CAP

*

4-IN. ROUND

ELBOW(S)

*

4-IN.

ROUND

DUCT

*

WALL

CAP

*

*

Purchase

separately

INSULATION

(Can be placed around and

over fan housing.)

FAN

HOUSING

HOUSING

MOUNTING

BRACKET

CEILING

JOIST

POWER

CABLE

TRIM RING / BAFFLE

FINISHED CEILING

4" ROUND

DAMPER/DUCT

CONNECTOR &

4” ROUND

DUCTWORK