PROGRAMMING

PROGRAMMING THE BREWER

The information in this manual covers only the differences between this model and the standard Axiom.

Access to service level 4 is same as standard Axiom.
The following function screens are in order of appearance. Each screen will have instructions on how to access,
and the procedures to program the various functions of the brewer.

IMPORTANT PROGRAMMING NOTES

- READ CAREFULLY -

To exit the programming mode at any time, press and release "ENABLE BREW ON/OFF" switch located on the

front switch panel. The display will return to the MAIN SCREEN.
If none of the programming switches are pressed within one minute during the setup of the brewer, the
programming of the function screen that is being set will be exited and the display will return to the MAIN
SCREEN.

Always remember to place an empty server and funnel under the sprayhead when operating the brewer dur-

ing the set-up of PULSE BREW, CALIBRATE FLOW and testing the brew valve in TEST OUTPUTS.

Push and hold left "hidden" but-

ton to access service program

modes.

READY TO BREW

WATER TEMP: 200°

LOCK

SET

PROGRAMMING LOCKOUT SWITCH

(Mounted on main control board)

This switch can be set to prevent access to the programming settings of the brewer. Once all the correct brew

settings are programmed, the operator can set the switch to the "LOCK" position to prohibit anyone from chang-

ing the settings. With the switch in the "LOCK" position, the programming menus can still be accessed to view

the current settings. However, no changes will be saved.