- 5 -

EXTERIOR OR IN-LINE BLOWER SELECTION

CAUTION: Either an exterior blower or in-line blower may be used with this hood.
The 63000EX series hood must be installed with blower models 331H, 332H, 335,
336, HLB3, HLB6, HLB9 or HLB11 only. Other Blowers cannot be substituted
(Blowers sold separately).
The blower must be UL listed for Canadian and U.S. use, and evaluated for use with
solid state speed control, rated 120V, 60 Hz, 6.0 A max.

8”ROUND

DUCT

INSTALL THE DUCTWORK

NOTE: To reduce the risk of fire, use only metal ductwork.

1. Choose the location where the Exterior or In-Line Blower will be mounted. See

illustrations below for mounting location suggestions and restrictions.

2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows and transitions will reduce the performance of the

hood. Use as few of them as possible. Larger ducting may be required for best
performance with long duct runs.

4. After the Exterior or In-Line Blower has been installed, connect round metal

ductwork and work back towards the hood location. Use duct tape to seal joints
between ductwork sections.

5. An 8” round to 10” round transition (Model 414) is required. For best air

performance, install the transition as close to the range hood as possible.

OK

OK

SUGGESTED MOUNTING LOCATIONS

EXTERIOR BLOWER

CAUTION: MAY NOT FIT

UNDER EAVES OF SINGLE

STORY HOMES

24” TO 30” ABOVE

COOKING SURFACE

DECORATIVE

FLUE

8” TO 10”

ROUND

TRANSITION

8” ROUND

ELBOW

10”

ROUND

DUCT

10” ROUND

DUCT

EXTERIOR

BLOWER

HOOD

EXTERIOR

BLOWER