Details of programming, Technical details – Beltronics V895 User Manual

Page 9

Advertising
background image

14

15

City Mode Sensitivity

City STD

(Standard)

In this setting, when you put your V895 in
the City mode, X-band sensitivity is
significantly reduced, to reduce annoyance
from X-band intrusion alarms and motion
sensors. (factory default)

City LoX

(Low X band sensitivity)

In this setting, when you put your V895 in
the City mode, X-band sensitivity is reduced
more than the standard setting. This will
reduce X-band alarms from other sources
even further, but also significantly reduces
range to X-band traffic radar.

City NoX

(No X-band sensitivity)

In this setting, when you put your V895 in
the City mode, V895 will not respond to
any X-band signals.

NOTE: These settings only apply
when the V895 is operated in City
mode. X-band sensitivity is not
affected when used in “AutoScan”
or “Highway” modes.

WARNING: Only choose this setting
if you are absolutely certain that
there are no X-band traffic radar
units where you drive.

Bands

BandsDFT
In this setting, all North American radar and
laser frequencies are monitored. This is the
factory setting and it is recommended that
you use your V895 in this mode.

BandsMOD
In this setting, your V895 will warn you
with an audible alert, and associated text
message stating which band has changed
from the original factory setting (i.e. “SWS
ON”). This warning is displayed during the
start up sequence (standard or fast).

Details of Programming

Features and Specifications

Operating Bands
• X-band 10.525 GHz ± 25 MHz
• K-band 24.150 GHz ± 100 MHz
• Ka-band 34.700 GHz ± 1300 MHz
• Laser 904nm, 33 MHz bandwidth

Radar Receiver / Detector Type
• Superheterodyne, VTO
• Scanning Frequency Discriminator
• Digital Signal Processing (DSP)

Laser Detection
• Quantum Limited Video Receiver
• Multiple Laser Sensor Diodes

Display Type
• 280 LED Alphanumeric
• Bar Graph
• 3 Levels of Brightness, plus Dark Mode

Power Requirement
• 12VDC, Negative Ground
• Power cord (included)

Programmable Features
• Power-On Indication
• Voice Alerts
• Power-On Sequence
• AutoMute
• City Mode Sensitivity
• Bands

Sensitivity Control
• Highway, AutoScan and City

Auto Calibration Circuitry

VG2 Immunity

Dimensions (Inches)
• 1.25 H x 2.75 W x 4.75 L

Patented Technology
The V895 is covered by one or more of the
following US patents.
6,693,578 6,614,385 6,587,068 6,400,305
6,249,218 6,069,580 5,668,554 5,600,132
5,587,916 5,559,508 5,365,055 5,347,120
5,446,923 5,402,087 5,305,007 5,206,500
5,164,729 5,134,406 5,111,207 5,079,553
5,049,885 5,049,884 4,961,074 4,954,828
4,952,937 4,952,936 4,939,521 4,896,855
4,887,753 4,862,175 4,750,215 4,686,499
4,631,542 4,630,054 4,625,210 4,613,989
4,604,529 4,583,057 4,581,769 4,571,593
4,313,216 D314,178 D313,365 D310,167
D308,837 D296,771 D288,418 D253,752
The V895 is also covered by one or more of
the following Canadian patents:
2,330,964 1,295,715 1,295,714 1,187,602
1,187,586
Other patents pending. Additional patents
may be listed inside the product.

Technical Details

17813_Vector895 Manual 3/21/05 8:18 AM Page 17

Advertising