Operating reliability – Beyerdynamic Revoluto Microphone User Manual

Page 7

Advertising
background image

7

OPERATING RELIABILITY

For each component in the MCS-Digital conference

system, which is connected via the NetRateBus

(cf. graphic), a high degree of operating reliability

has been integrated.

THE CONTROL UNIT

Parallel to the control unit, a second control unit can

be integrated in the system as backup.

THE WIRING

The microphone stations and the control unit can

be wired in a closed loop.

THE POWER SUPPLY

If a power supply fails or is switched off for

maintenance, the power reserve automatically

distributes itself throughout the network.

THE MICROPHONE STATION

During a running conference, faulty microphone

stations can be replaced or additional micro-

phone stations can be integrated by hot plug-

ging.

DATA SECURITY

Additional data connections as redundancy for

specific sections or the entire network can be

directly connected to the control unit.

5

4

3

2

1

CU

CU

PS

PS

2

4

3

5

1

B

A

One of the possible conference requirements

(two different rooms) with optimum operating

reliability. Conferences can be held simultaneously

and independently of each other here.