CONNECT THE DUCTWORK

Duct tape all connecton’s to make them

secure and air tight.

DUCTED HOODS ONLY
1. Connect 6” diameter metal duct to ducting

that discharges to the outside.

NON-DUCTED HOODS ONLY
2. Connect 5” diameter expandable metal

duct from the non-ducted plenum to the

adapter on the blower discharge.

DUCTED AND NON-DUCTED HOODS
3. Remove the tape from the lower flue.

Lower the flue until is seats on top of the

hood.

4. Remove duct tape from upper and lower

flue. Lower the flue until it seats on top of

the hood.

6” DUCTED

CONNECTION

WIRING BOX

COVER

LINE IN 120 VOLTS - 60 HZ

WIRE CLAMP

BLK-BLK

WHT-WHT

GRN-GRN

INSTALL ELECTRICAL

WARNING: Electrical wiring must be done by a qualified person(s) in

accordance with all applicable codes and standards. This range hood must be

properly grounded. Turn off electrical power at service entrance before wiring.
1. Remove the wiring box cover. Fig. 20.
2. Run 2-wire plus ground power cable through the round opening in the support

frame bracket and into the wiring box.

3. Secure cable to box with an appropriate cable connector.
4. Feed the range hood’s power cable through the hole in the bottom of the

wiring box.

5. Secure the cable to the box using the wire clamp (supplied in the parts bag).
6. Connect wires, white-to-white, black-to-black and green-to-ground.
7. Push wiring into the electrical box. Reinstall the wiring box cover.
8. Raise the upper flue and reinstall mounting screws.