Maintenance 21 – Breckwell P2000FS User Manual

Page 21

Advertising
background image




CHIMNEY CLEANING

a.

Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a newly started fire or from a slow-
burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire,
which may damage the chimney or even destroy the house. Despite their high efficiency, pellet stoves can accumulate creosote under
certain conditions.

b.

Fly Ash – This accumulates in the horizontal portion of an exhaust run. Though noncombustible, it may impede the normal exhaust
flow. It should therefore be periodically removed.

c.

Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or
fly ash build-up has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire. Inspect the
system at the stove connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to
check the chimney from the top as well as from the bottom.


The creosote should be removed with a brush specifically designed for the type of chimney in use. A qualified chimney sweep can perform
this service. It is also recommended that before each heating season the entire system be professionally inspected, cleaned and, if
necessary, repaired.

To clean the chimney, detach the vent at the combustion blower transition where it is attached to the blower. (See figure 28 for the P2000
Insert)

RECOMMENDED MAINTENANCE SCHEDULE

Use this as a guide under average-use conditions.

Daily

Weekly

Bi-Annually

Annually or per Ton

Burn Pot

Stirred

Emptied

Glass

Wiped

Cleaned

Combustion Chamber

Brushed

Ashes

Emptied

Interior Chambers

Vacuumed

Heat Exchange Tubes

Two passes

Combustion Blower Blades

Vacuumed / Brushed

Convection Blower Impeller

Vacuumed / Brushed

Vent System

Cleaned

Gaskets

Inspected

Hopper (end of season)

Emptied and vacuumed


Gasket around door and door glass should be inspected and repaired or replaced when necessary (see “REPLACEMENT PARTS”).

REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS

While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the
doorframe. Dispose of all broken glass properly. Return the damaged door to your Breckwell Dealer for repair or replacement.
Neither the appliance owner nor any other unauthorized person(s) should replace the door glass. An authorized Breckwell dealer must
perform all repairs involving door glass.

FIGURE 27b

MAINTENANCE

21

FIGURE 27a

Advertising