Application: User can choose that they want.

Outgoing Incoming: Determine whether the rule is for outgoing packets or for

incoming packets.

Active: Choose “Yes” to enable the rule, or choose “No” to disable the rule.

Packet Type: Specify the packet type (TCP, UDP, ICMP or any) that the rule applies to.

Select TCP if you wish to search for the connection-based application service on the remote

server using the port number. Or select UDP if you want to search for the connectionless

application service on the remote server using the port number.

Log: Choose “Yes” if you wish to generate logs when the filer rule is applied to a packet.

Action When Matched: If a packet matches this filter rule, Forward or Drop this packet.

Source IP Address: Enter the incoming or outgoing packet’s source IP address(es).

Source Port: Check the TCP or UDP packet’s source port number(s).

Destination IP Address: Enter the incoming or outgoing packet’s destination IP

address(es).

Destination Port: Check the TCP or UDP packet’s destination port number(s).