Blanco BRU7G User Manual

Page 6

Advertising
background image

- 6 -

it 90 degrees until the stop click is heard to lock it (F) fig. 3. Remove the grills (G) fig. 3 to carry out
this operation. The air is released in the room through a connecting pipe, which goes through the
hanging cupboard and which is connected to the connecting ring supplied (B) fig. 1.

Recirculated to kitchen area via

Recirculated to kitchen area via ceiling

Ducted to atmosphere through wall

Ducted to atmosphere through roof

Rangehood Installation
Exercise care when a rangehood is installed in an area where a gas burner is operating. Depending
on the size of the room, the rangehood may draw from the room air that is necessary for proper
combustion of the burner. All Blanco rangehoods are used for indoor application only.

Rangehoods may be installed in two ways:
1. Ducted to the atmosphere (outside).
2. Recirculating.
We recommend ducting to the atmosphere to ensure optimum performance. Recirculating the air
back into the room should only be used when outside extraction is not possible. To ensure maximum

Advertising
This manual is related to the following products: