PREPARE THE FAN

1. Remove the screw holding the blower assembly in place. Lift

assembly from housing.

2. Slide adjustable mounting brackets into bracket channels on

housing. NOTE: Housing may be mounted directly to joist
using keyholes provided.

INSTALL THE FAN

1. Position housing between joists and extend mounting brack-

ets. Position brackets such that bottom edge of housing will be
flush with finished ceiling. Mark the top of keyhole on all four
mounting brackets.

2

INSTALL THE FAN

(CONT'D)

Е

Е

2. Remove housing temporarily, and pound nails partially into

joists at all four marked locations.

3. Hang housing from nails. Use measuring guides on corners of

housing to check if unit will be flush with finished ceiling. Pound
nails tight. For wide joist centers: A #8 x 3/8 self-tapping screw
can be used to join extended brackets together and create a
rigid mount. To ensure a noise-free mount, crimp the bracket
channels tightly around mounting brackets.

4. Snap the damper/duct connector onto housing. Make sure that

tabs on the duct connector lock in housing slots and that gravity
closes damper.

5. Install 4” round duct and extend duct to outside through a roof

or wall cap. Check damper to make sure that it opens freely.
Tape all duct connections to make them secure and air tight.

1½" FOR

½" DRYWALL