Accessories, Side filter rack* dimensions (in.) – Bryant 340AAV User Manual

Page 12

Advertising
background image

—12—

ACCESSORIES

SIDE FILTER RACK*

DIMENSIONS (In.)

* Dimension A will change accordingly as dimension D is lengthened or shortened.

† Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by

cutting the pipes provided in the kit to 12 in. minimum.

* The plenum should be constructed 1/4 in. smaller in width and depth than the plenum dimensions shown above.

PART NO.

A*

B

C

D†

E

F

KGAVT0501CVT

33-3/8

2

3-1/2

16-5/8

6-1/4

5-3/4

KGAVT0601CVT

38-7/8

3

4-1/2

21-1/8

7-3/8

6-1/2

FURNACE

CASING

WIDTH

FURNACE IN DOWNFLOW APPLICATION

PLENUM OPENING*

FLOOR OPENING

HOLE NO.

FOR WIDTH

ADJUSTMENT

A

B

C

D

17-1/2

Furnace with or without Cased Coil

Assembly or Coil Box

15-1/8

19

16-3/4

20-3/8

3

21

Furnace with or without Cased Coil

Assembly or Coil Box

18-5/8

19

20-1/4

20-3/8

2

24-1/2

Furnace with or without Cased Coil

Assembly or Coil Box

22-1/8

19

23-3/4

20-3/8

1

17

1

8

14 1⁄2″

OPENING

16

1

8

23

1

8

OPENING

1

1

4

2

3

8

3

4

1

2

25

1

8

1

1

4

″ (TYP)

3

8

TABS

A80199

* Accepts one 16 x 25 x 1 in. filter.

LOCATING

TAB

LOCATING

TAB

1

2

3

4

4

3

2

1

B

D

C IN. DIA

B IN. DIA PVC
VENT/EXHAUST

1

3

/

16

B IN. DIA PVC
INTAKE/COMBUSTION AIR

D

E

F

A

1

1/2

;;;;

;;;;

C

A

1

1

/

4

″ TYP

PLENUM
OPENING

FACTORY-SUPPLIED

FIELD-INSTALLED

INSULATION

NOTE: See furnace Installation Instructions when venting multiple
furnaces near each other.

A88207

A96211

CONCENTRIC VENT FOR DIRECT VENT (2-PIPE) APPLICATION

A96211

FIELD-SUPPLIED
2-IN. DIAMETER
PVC PIPE

FIELD-SUPPLIED
2-IN. DIAMETER
PVC 90° ELBOW

COMBUSTION-AIR DISC
(FACTORY-SUPPLIED IN
LOOSE PARTS BAG)

A

Combination-Air Pipe for Non-Direct Vent (1-Pipe)

Application (Sizes 040 Through 120 Only)

Disassembled

Assembled

(ALL MODEL SIZES)

ACCESSORY DOWNFLOW SUBBASE

LENGTH OF STRAIGHT

PIPE PORTION OF COMBUSTION

AIR INLET PIPE ASSEMBLY (IN.)

CASING WIDTH

A

17-1/2

8-1/2 ± 1/2

21

10-1/2 ± 1/2

24-1/2

12 ± 1/2

Advertising